Group 8
Job Editor
Page 83
JET3up
Release R1.06
6.5.3.2
Switching on with password protetction
Proceeding:
Touch the dark
Touch-Display
(1)
for at least 2 seconds.
The device turns on and the main window
(3)
is displayed with the message
<Initialization>
(2)
.
After the initialization the device starts with the bleeding of the system
automatically.
During the process the
message <Bleeding>
(4)
is displayed. The bleeding
takes between 1 – 5 min. The process can be canceled by pressing the button
<Cancel>
(5)
.
Note:
The start of the device happens in the logged-out status (no operator will be
logged on) but the job which has been used at last will be loaded automatically.
The dialog field
<Current login>
(6)
and a keyboard field
(8)
pops up.
INFORMATION
You will find further information regarding the operation with
keyboard in the
Enter your password with the keyboard field.
Press the button
<Enter>
(9)
of the keyboard field to finish the input.
Now press the button
<Login>
(10)
to finish the login.
Now the user is logged-in and the active password level is displayed on top right
of the title bar
(11)
.
ATTENTION
The login can be also carried out without a password. In this case
only several basic functions of the device are available for the
user.
You will find further information in the
Summary of Contents for JET3 up
Page 1: ...Operating Manual V1 06 Please keep for future reference ...
Page 2: ......
Page 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Page 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Page 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Page 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Page 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Page 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...