Basic data /Recommended working conditions:
Signal
Parameter
Value
All signals
Input level High
15 up to 30V
Input level Low
-3,5V up to 3,5V
(or high resistance)
Input resistance
6,8kOhm
Increment Counter/
Reset Counter
Minimum pulse width
250µs
Power ON
Minium pulse width
2,5 s
Jobselect 0-9
Maximum duration
of bounce
10 ms
(2)
Input 0-5
Minimum pulse widths
Depending on assigned function
(see following table)
In the following table you will find the minimum pulse widths which are required to
release the assigned function at the X4 plug.
Function
Minium pulse width
Open nozzle
300ms
Close nozzle
300ms
Print start
500ms
Print stop
500ms
Turn off printer
750ms
Mirrored horizontally
200ms
Gauger synchronization signal
200ms
INFORMATION
The function allocations of the inputs 0 up to 5 happens by the
software of the JET3up in the menu
Settings
I/O-Settings
Inputs
.
You will find a circuit diagram of the interface in the manual
appendix!
(1)
all 24V power supply outputs on X1, X3, X4 and X5 are distributed over a common resettable
fuse with 700mA max. current.
Please ensure that the sum of current are not exceed 700 mA.
(2)
If one or more of the jobselect inputs were changed the changes must be completed
( = all signals are stable) within this time.
Summary of Contents for JET3 up
Page 1: ...Operating Manual V1 06 Please keep for future reference ...
Page 2: ......
Page 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Page 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Page 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Page 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Page 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Page 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...