Group 8
Job Editor
Page 281
JET3up
Release R1.06
Information
Encoder guidelines and “hot-plugging” of
8.5.3.1
Encoder source - StrokeGo-source
There are three options in order to define the
<StrokeGo>
source:
Internal:
If this function is activated, the signal is generated by the printer and
needs no external encoder device.
Additionally you have to enter the
<Internal speed (intern Speed)>
(3)
.
ATTENTION
The internal encoder source is only recommended for constant
printing speeds.
You will find further information regarding this topic in the chapter
External:
If this function is activated signals from an external encoder (e.g. incremental
encoder) are required. The encoder has to be connected to the interface X1 of
the LEIBINGER JET3up.
Additionally you have to define the
<Encoder/Direction>
(4)
and the
<Resolution>
(5)
.
Sensor measurement:
If this function is activated the JET3up printer expects 2
sensor signals in order to calculate the required printing speed. The
<StrokeGo>
signals are generated on the basis of the calculated speed.
Figure 155 StrokeGo-source /Encoder source
1 – Check box <Encoder source int.>
3 – Display field <Internal speed>
2 – Check box <Encoder source ext.>
4 – Check box <Sensor Measurement>
2
3
4
1
Summary of Contents for JET3 up
Page 1: ...Operating Manual V1 06 Please keep for future reference ...
Page 2: ......
Page 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Page 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Page 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Page 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Page 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Page 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...