Page 52
Transport/Start up
Group 5
Release R1.06
JET3up
Proceeding (Example: Filling of solvent)
WARNING
Risk of fire and injury! Absolutely observe!
Before filling the device with the consumables, measures for the
electrostatic discharge have to be made!
Highly flammable! Burning gases and liquids may cause severe
burns. Keep sources of ignition away from the printer!
Always statically discharge the printer and yourself before filling
the reservoirs! Simply touch the housing of the printer to discharge
the equipment and stand on a grounded surface wearing ESD
shoes during filling!
Protective equipment is necessary! Read the safety data sheets
and the personal protective equipment rules and regulations!
ATTENTION
The sealing of the refill bottle
must not be opened
!
Open the lid
(2)
of the reservoir tank unit
(1)
.
Open the screw cap of the solvent tank
(4)
and of the refill bottle
(5)
.
Put the refill bottle on the solvent tank. The seal of the bottle will be breached
and the closing valve of the tank will open automatically and the reservoir tank
is filled up.
Wait until the refill bottle is completely empty.
Take out the empty refill bottle. The closing valve of the reservoir tank will be
closed automatically.
Finally close the reservoir tank and empty refill bottle carefully with the srew
caps.
ATTENTION
The reservoir tanks as well as the empty refill bottles have to be
closed carefully after filling.
Summary of Contents for JET3 up
Page 1: ...Operating Manual V1 06 Please keep for future reference ...
Page 2: ......
Page 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Page 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Page 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Page 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Page 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Page 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...