Page 152
Job Editor
Group 8
Release R1.06
JET3up
Functional descriptions
Pressure (4)
This is the setpoint of the pressure of the hydraulic circuit in [mbar].
Suction pump (5)
The suction pump works at partload. The partload value is defined percentage of
the full load.
Visco correction (6)
The printer is supplied with a factory calibrated viscometer. The
<Visco
correction>
is used for such calibrating purposes.
Fall time (7)
This is the setpoint for the viscosity of the current ink.
Nozzle (8)
The size of the nozzle of the printer in [µm].
Oscillator Voltage (9)
The setpoint of the oscillator voltage. This value is only adjustable through a special
service access.
Ink number (10)
The number of the currently used ink.
Solvent number
(11)
The number of the solvent suitable for the current ink. This value is set
automatically dependent on the current ink.
Frequency
(12)
The setpoint of the frequency of the oscillator.
Indicators for current values (13)
The pressure within the hydraulic circuit, the power consumption of the suction
pump and the falltime (viscosity) are constantly measured and indicated.
Spin buttons for settings (14)
All setpoints can be changed by using the spin buttons of the respective input
fields.
Drop-down list <Ink number> (15)
The drop-down list shows the available inks.
Drop-down list <Frequencies> (16)
The drop-down list shows the available frequencies.
Summary of Contents for JET3 up
Page 1: ...Operating Manual V1 06 Please keep for future reference ...
Page 2: ......
Page 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Page 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Page 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Page 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Page 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Page 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...