Group 8
Job Editor
Page 135
JET3up
Release R1.06
Proceeding:
Press on the tab
< Interfaces>
(2)
to select the tab.
Press on the arrow key of the drop-down list
<Encoder Settings>
(3)
. The
drop-down list opens for selection.
Now select the required interface.
If required activate now the bounce time delay by clicking on the check box
(4)
.
An activated delay is displayed by
√
in the check box.
Figure 50
Select encoder interface
Bounce time delay is switched off
Bounce time delay is switched on
1 –Dialog box <Basic Settings>
3 – Drop-down list <Encoder settings>
2 –Tab < Interfaces>
4 – Check box <Bounce time delay off>
Pos. Interface
Describtion
1.
RS422
5V / 4 Signals (A,
Ā
, B, B)
2.
TTL
5V TTL / 2 Signals (A, B)
3.
HTL
24V / 2 Signals (A, B)
2
1
3
4