Requirements for insulation, heating and ventilation
The bulkheads in the sonar room must be insulated and provided with an interior wall to
the deck. The room must be equipped with heater, and it must be connected to the vessel's
ventilation system.
Insulation requirements
The insulation in the sonar room should be the minimum equivalent of 50 mm of rock-wool.
Piping passing through the space prone to condensation must be properly insulated.
Heating requirements
Heating is an effective method for reducing humidity. The heater in the sonar room must be
dimensioned to maintain the equipment within its environmental tolerances. Typical heating
power is minimum 1000 W. The heater must be installed close to the deck.
Ventilation requirements
The sonar room must be connected to the vessel's ventilation system to ensure a supply of
cooling air. If a ventilation system is not available, install two 3” pipes from the sonar
room to a suitable fresh air location on deck.
The fresh air should enter the room as close to the floor as possible, and should be extracted
from as high as possible. A funnel shaped drip-collector must be mounted below the vent
pipes to divert moisture to the bilge. On the main deck, the best ventilation is provided when
the outlet pipe is at least four meters higher than the inlet pipe. To keep out sea water, rain
and spray, the ventilation pipes must be fitted with goosenecks or an equivalent design.
Note
If the vessel is likely to operate in tropical conditions, a suitable air conditioning system
must be installed. The air conditioning system must be able to provide an ambient
temperature that does not exceed the maximum operating temperatures of the system units
that are installed in the room.
Related topics
Summary of Contents for Simrad MF90
Page 1: ...kongsberg com simrad Simrad MF90 INSTALLATION MANUAL...
Page 2: ......
Page 21: ...476671 B 19 Related topics Simrad MF90 page 13 Simrad MF90...
Page 369: ...476671 B 367 Drawing file...
Page 372: ...370 476671 B Simrad MF90 Installation Manual...
Page 375: ...476671 B 373 Drawing file...
Page 378: ...376 476671 B Simrad MF90 Installation Manual...
Page 384: ...382 476671 B Simrad MF90 Installation Manual...
Page 387: ...476671 B 385 Drawing file...
Page 390: ...388 476671 B Simrad MF90 Installation Manual...
Page 393: ...476671 B 391 Drawing file...
Page 398: ...396 476671 B Simrad MF90 Installation Manual...
Page 421: ......
Page 422: ...2022 Kongsberg Maritime ISBN 978 82 8066 240 8...
Page 423: ......
Page 425: ......
Page 426: ...Installation Manual Simrad MF90...