![Kongsberg Simrad MF90 Installation Manual Download Page 173](http://html1.mh-extra.com/html/kongsberg/simrad-mf90/simrad-mf90_installation-manual_1992582173.webp)
476671/B
171
Powered audio output
The Processor Unit offers a powered audio output. One or two loudspeakers can be
connected to the output. The output is rated to 2 W for each channel.
You need a 9-pin male D-Subminiature connector. This is a
commercial item that can be purchased locally.
Note
This connection is specific for the HT20470 computer.
Pin
Signal
1
Left channel
2
Left channel / Ground
3
Right channel
4
Right channel / Ground
5-9
Not used
Minimum cable requirements
•
Conductors
: 2 x 0.25 mm
2
•
Screen
: None
•
Voltage
: 24 V
•
Maximum outer diameter
: Defined by the plugs and/or the gable gland
Related topics
Cable layout and interconnections, page 143
Cable plans, page 145
Installing the MF90 cables, page 154
Cable drawings and specifications, page 164
Summary of Contents for Simrad MF90
Page 1: ...kongsberg com simrad Simrad MF90 INSTALLATION MANUAL...
Page 2: ......
Page 21: ...476671 B 19 Related topics Simrad MF90 page 13 Simrad MF90...
Page 369: ...476671 B 367 Drawing file...
Page 372: ...370 476671 B Simrad MF90 Installation Manual...
Page 375: ...476671 B 373 Drawing file...
Page 378: ...376 476671 B Simrad MF90 Installation Manual...
Page 384: ...382 476671 B Simrad MF90 Installation Manual...
Page 387: ...476671 B 385 Drawing file...
Page 390: ...388 476671 B Simrad MF90 Installation Manual...
Page 393: ...476671 B 391 Drawing file...
Page 398: ...396 476671 B Simrad MF90 Installation Manual...
Page 421: ......
Page 422: ...2022 Kongsberg Maritime ISBN 978 82 8066 240 8...
Page 423: ......
Page 425: ......
Page 426: ...Installation Manual Simrad MF90...