5.3.1 Configuring which alerts to monitor
Before configuring the method of sending the alert to IBM Director, you should
first define which events the Remote Supervisor Adapter is to send.
To enable alerting on the Remote Supervisor Adapter, do the following:
1. From the Web browser main menu, click Alerts in the navigation bar.
2. Scroll to the Monitored Alerts section. There are three types of events listed,
as follows:
– Critical Alerts: These are hard disk drive, multiple fan failure, power failure,
tamper, temperature, voltage, and VRM failure
– Warning Alerts: These are single fan failure, temperature, voltage, and
redundant power supply
– System Alerts: These are boot failure, loader timeout, O/S timeout, PFA,
POST timeout, power off, and power on
3. Select the events you wish to monitor. We recommend you enable all events.
See Figure 5-6 on page 189.