D00461-10
D00462-10
-4!)
16 BRAKE SYSTEM
(FE EU/AU, FE 350 US)
- Move the brake fluid reservoir mounted on the handlebar
to a horizontal position.
- Cover painted parts.
- Remove screws
O.
- Take off cover
8
with the membrane.
- Draw the old brake fluid out of the brake fluid reservoir
using a syringe and fill with fresh brake fluid.
Syringe (50329050000) (
�
p. 358)
Brake fluid DOT 4 (
!!.,!I
p. 352)
- Mount bleeder cover
@).
I Bleeder cover (00029013005) (
l!!ll
p. 356)
- Connect the bleeding device.
I Bleeding device (00029013100) (
�
p. 356)
- Open shut-off valve
C,.
Info
Follow the operating instructions of the bleeding
device.
- Ensure that the filling pressure is set on pressure
gauge f). Correct the filling pressure on pressure
regulator G) if necessary.
Guideline
I Filling pressure
I 2 ... 2.5 bar (29 ... 36 psi)
- Pull off protection cap
0
of the brake caliper bleeder
screw. Connect the bleeder bottle hose.
I Bleeding device (00029013100) (
�
p. 356)
- Open bleeder screw
0)
by approx. one half turn.
•
Info
I
Drain until fresh brake fluid emerges in the bleeder
bottle hose without bubbles.
- Tighten the bleeder screw.
- Close shut-off valve
C,.
- Open the bleeder screw again until brake fluid stops
emerging.
•
Info
I
Overfilling of the brake fluid reservoir is prevented.
- Tighten the bleeder screw. Remove the bleeder bottle
hose. Attach the protection cap.