6 FORK, TRIPLE CLAMP
Disassembling the cartridge
Info
The procedures are the same on both fork legs.
202480-10
=(fplt==------====-
R00023-10
Preparatory work
-
Disassemble the fork legs. (
a
p. 20)
-
Remove the spring. (
a
p. 22)
Main work
-
Degrease piston rod
O
and clamp using the special tool.
I
Clamping stand (T14049S) (
�
p. 370)
-
Remove adjusting tube@. Unscrew spring guide (5).
-
Remove spring seat
C,.
-
Pull the piston rod out of the cartridge.
-
Degrease the cartridge and clamp it with the special tool.
I
Clamping stand (T14049S) (
a
p. 370)
-
Release seal ring retainer
0
and remove with the washer.
-
Remove lock ring
(D.
-
Pull reservoir @ out of the cartridge.