202090-10
201701-11
201700-11
6 FORK, TRIPLE CLAMP
- Pull out the piston rod and push it back in numerous times
while pressing it to one side slightly.
✓ Air bubbles emerge and the cartridge is bled.
- Keep bleeding until no more air bubbles emerge.
✓ The piston rod automatically moves out to the center of
the full stroke.
Info
When fully bled, the correct air chamber length is
achieved.
- Position the spring.
- Pull the spring downward. Mount screw cap@).
Info
When assembling, ensure that the screw caps are cor
rectly mounted according to the hydrostop needles.
Rebound damping side - red hydrostop needle, screw
cap with mark REB.
Compression damping side - silver hydrostop needle,
screw cap with mark
COMP.
- Mount the open end wrench on the hexagonal part.
- Hold the open end wrench. Tighten screw cap @).
Guideline
Screw cap on piston M8x0. 75
rod
I
Mounting tool (T14047) (!!:!Ip. 370)
- Push the outer tube upward.
18 Nm (13.3 lbf ft)
- Clamp the outer tube in the area of the lower triple clamp.
I
Clamping stand (T1403S) (
!!:!I
p. 370)
- Tighten screw cap @).
Guideline
Cartridge on outer
tube
M51x1 .5
I
Mounting tool (T14047) (
!l.,!l
p. 370)
- Mount the adjuster.
- Mount and tighten screw
0.
Guideline
40 Nm (29.5 lbf ft)
I
Screw, adjuster
I M4x0.5
I 2.5 Nm (1 .84 lbf ft)
35