201
Chapter 13
MtcMon Messages
IOPn.MtcMon FRU Messages
IOPn.MtcMon FRU: CEx MIC fault.
Variables
x – the ID of the CE with the MIC fault
Severity
Error
Description
The MIC adapter on the specified CE is malfunctioning. Usually this indicates that the MIC
adapter is neither receiving nor transmitting messages properly and is probably due to a
hardware problem with the specified MIC.
Action
•
Run the MIC Connectivity Test in the MIC BIOS utility to validate that the paths between
the CE and the Endurance server are functioning properly.
•
Replace the MIC if it appears to be faulty.
IOPn.MtcMon FRU: CEx Power supply failure.
Variables
x – the ID of the CE with the power supply failure
Severity
Error
Description
The power supply to the specified CE was interrupted.
Action
•
Make sure that the CE has not been powered off.
•
Check the power supply connections to the specified CE.
•
Check the internal power supply function of the CE.
•
Make sure that line voltage is within operational parameters for the CE.
•
Replace the CE MIC.
Summary of Contents for NetServer AA 4000
Page 1: ...HP NetServer AA Solution Messages HP Part Number 5969 5966 Printed in September 2000 ...
Page 6: ...Contents vi ...
Page 8: ...Tables viii ...
Page 52: ...Chapter 1 Introduction 42 ...
Page 70: ...Chapter 2 MIC BIOS Messages 60 ...
Page 98: ...Chapter 4 MtcCEX Messages 88 ...
Page 119: ...109 Chapter 6 MtcDsl Messages ...
Page 120: ...Chapter 6 MtcDsl Messages 110 ...
Page 154: ...Chapter 8 MtcEvtP Messages 144 ...
Page 162: ...Chapter 9 MtcFLOP and MtcFLOR Messages 152 ...
Page 166: ...Chapter 10 MtcIopDm Messages 156 ...
Page 372: ...Chapter 16 MtcVidP Messages 362 ...
Page 378: ...Chapter 17 MtcVnP Messages 368 ...