Fabric OS Administrator’s Guide
57
53-1002446-01
Track and control switch changes
3
WWN
0
0
CP
0
0
Blade
0
0
CoreBlade
0
0
Flash
0
0
MarginalPorts
0.00%[0]
0.00%[0]
FaultyPorts
0.00%[0]
0.00%[0]
MissingSFPs
0.00%[0]
0.00%[0]
ErrorPorts
0.00%[0]
0.00%[0]
Number of ports: 4
Setting the switch status policy threshold values
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the switchStatusPolicySet command.
The current switch status policy parameter values are displayed. You are prompted to enter
values for each DOWN and MARGINAL threshold parameter.
NOTE
By setting the DOWN and MARGINAL values for a parameter to 0,0 that parameter is no longer
used in setting the overall status for the switch.
3. Verify the threshold settings you have configured for each parameter.
Enter the switchStatusPolicyShow command to view your current switch status policy
configuration.
Example output from a switch
The following example displays what is typically seen from a Brocade switch, but the quantity and
types vary by platform.
switch:admin>
switchstatuspolicyshow
To change the overall switch status policy parameters
The current overall switch status policy parameters:
Down
Marginal
-----------------------------------
PowerSupplies
2
1
Temperatures
2
1
Fans
2
1
Flash
0
1
MarginalPorts
25.00%[12]
10.00%[5]
FaultyPorts
25.00%[12]
10.00%[5]
MissingSFPs
0.00%[0]
0.00%[0]
ErrorPorts
0.00%[0]
0.00%[0]
Number of ports: 48
Note that the value, 0, for a parameter, means that it is
NOT used in the calculation.
** In addition, if the range of settable values in the prompt is (0..0),
** the policy parameter is NOT applicable to the switch.
** Simply hit the Return key.
The minimum number of
Bad PowerSupplies contributing to DOWN status: (0..2) [2]
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...