Fabric OS Administrator’s Guide
291
53-1002446-01
Troubleshooting TI zone routing problems
12
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the zone
--
show command.
zone --show
[
name
] [-ascending]
To display information about the TI zone purplezone:
switch:admin>
zone --show purplezone
Defined TI zone configuration:
TI Zone Name:
redzone:
Port List:
1,2; 1,3; 3,3; 4,5
Configured Status: Activated / Failover-Enabled
Enabled Status: Activated / Failover-Enabled
To display information about all TI zones in the defined configuration in ascending order:
switch:admin>
zone --show -ascending
Defined TI zone configuration:
TI Zone Name:
bluezone:
Port List:
8,3; 8,5; 9,2; 9,3;
Configured Status: Deactivated / Failover-Disabled
Enabled Status: Activated / Failover-Enabled
TI Zone Name:
greenzone:
Port List:
2,2; 3,3; 4,11; 5,3;
Configured Status: Activated / Failover-Enabled
Enabled Status: Activated / Failover-Enabled
TI Zone Name:
purplezone:
Port List:
1,2; 1,3; 3,3; 4,5;
Configured Status: Activated / Failover-Enabled
Enabled Status: Deactivated / Failover-Enabled
Troubleshooting TI zone routing problems
Use the following procedure to generate a report of existing and potential problems with TI zones.
The report displays an error type.
•
“ERROR” indicates a problem currently exists in the fabric.
•
“WARNING” indicates that there is not currently a problem, given the current set of online
devices and reachable domains, but given the activated TI zone configuration, parallel
exclusive paths between a shared device and a remote domain have been detected, which
might cause a problem for devices that join the fabric later.
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the zone
--
showTIerrors command.
zone --showTIerrors
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...