![HP Fabric OS v7.0.1 Administrator'S Manual Download Page 243](http://html.mh-extra.com/html/hp/fabric-os-v7-0-1/fabric-os-v7-0-1_administrators-manual_165056243.webp)
Fabric OS Administrator’s Guide
205
53-1002446-01
Test and restore firmware on switches
9
User Name:
userfoo
File Name:
/home/userfoo/v7.0.0
Password:
<hidden>
Do Auto-Commit after Reboot [Y]:
n
Reboot system after download [N]:
y
Firmware is being downloaded to the switch. This step may take up to 30
minutes.
Checking system settings for firmwaredownload...
The switch performs a reboot and comes up with the new firmware to be tested. Your current
switch session automatically disconnects.
ATTENTION
Downloading firmware to a switch can be disruptive to switch traffic.
7. Connect to the switch, log in as admin, and enter the firmwareShow command to confirm that
the primary partition of the switch contains the new firmware.
You are now ready to evaluate the new version of firmware.
ATTENTION
Stop! If you want to
restore
the firmware, stop here
and skip ahead to
step 9
; otherwise,
continue to
step 8
to commit the firmware on the switch, which completes the firmware
download operations.
8. Commit the firmware.
a. Enter the firmwareCommit command to update the secondary partition with new firmware.
Note that it takes several minutes to complete the commit operation.
b. Enter the firmwareShow command to confirm both partitions on the switch contain the
new firmware.
ATTENTION
Stop! If you have completed
step 8
, then you have committed the firmware on the switch and
you have completed the firmware download procedure.
9. Restore the firmware.
a. Enter the firmwareRestore command. The switch reboots and comes up with the original
firmware again.
A firmwareCommit automatically begins to copy the original firmware from the primary
partition to the secondary partition. At the end of the firmware commit process, both
partitions have the original firmware. Note that it takes several minutes to complete the
commit operation.
b. Wait five minutes to ensure that all processes have completed and the switch is fully up
and operational.
c. Log in to the switch. Enter the firmwareShow command and verify that both partitions on
the switch have the original firmware.
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...