FC router port cost configuration
24
Every IFL has a default cost. The default router port cost values are:
•
1000 for a legacy (v5.1 or XPath FCR) IFL
•
1000 for an EX_Port IFL
•
10,000 for a VEX_Port IFL
The FC router port cost settings are 0, 1000, or 10,000. If the cost is set to 0, the default cost will
be used for that IFL. The FC router port cost is persistent and is saved in the existing port
configuration file.
FC router port cost is passed to other routers in the same backbone. Link costs from the front
domain to the translate (xlate) domain remain at 10,000. You can use the lsDbShow command
from the edge fabric to display these link costs.
Port cost considerations
The router port cost has the following considerations:
•
Router port sets are defined as follows:
-
0–7 and FCIP Tunnel 16–23
-
8–15 and FCIP Tunnel 24–31
•
The router port cost does not help distinguish one IFL (or EX_ and VEX_Port link) from another,
if all the IFLs are connected to the same port set. Therefore, if you connect IFL1 and IFL2 to the
same edge fabric in port set 0–7 and then configure them to different router port costs, traffic
is still balanced across all the IFLs in the same port set.
•
Use proper SAN design guidelines to connect the IFLs to different port sets for effective router
port cost use. For example, if both a low-speed IFL and a high-speed IFL are going to the same
edge fabric, connect the lower router cost IFL to a separate port group (for example, ports 0–7)
than the higher router cost IFL (for example, ports 8–15). For VEX_Ports, you would use ports
in the range of 16–23 or 24–31.
You can connect multiple EX_Ports or VEX_Ports to the same edge fabric. The EX_Ports can all be
on the same FC router, or they can be on multiple routers. Multiple EX_Ports create multiple paths
for frame routing. Multiple paths can be used in two different, but compatible, ways:
•
Failing over from one path to another.
•
Using multiple paths in parallel to increase effective data transmission rates.
EX_Ports and VEX_Ports, when connected, are assigned different router port costs and traffic will
flow only through the EX_Ports. Routing failover is automatic, but it can result in frames arriving out
of order when frames take different routes. The FC router can force in-order delivery, although
frame delivery is delayed immediately after the path failover.
Source EX_Ports can balance loads across multiple destination EX_Ports attached to the same
edge fabric using exchange IDs from the routed frames as keys to distribute the traffic.
Setting router port cost for an EX_Port
The router port cost value for an EX_Port is set automatically when the EX_Port is created. However,
you can modify the cost for that port. You can configure the EX_Port or VEX_Port with values of
either 1000 or 10,000. If you want to differentiate between two EX_Port links with different speeds,
you can assign 1000 to one link and 10,000 to the other link.
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...