
444
Fabric OS Administrator’s Guide
53-1002446-01
F_Port trunking
22
NOTE
You do not need to manually map the host to the master port because Access Gateway will perform
a cold failover to the master port.
See
“Configuring F_Port trunking for Access Gateway”
on page 447 for instructions on configuring
F_Port trunking.
Requirements for F_Port trunking on an Access Gateway
In addition to the requirements listed in
“Requirements for trunk groups”
on page 435, refer to the
Access Gateway Administrator’s Guide
for additional requirements that are specific to F_Port
trunking on an Access Gateway.
F_Port trunking for Brocade adapters
You can configure trunking between the F_Ports on an edge switch and the Brocade adapters.
In addition to the requirements listed in
“Requirements for trunk groups”
on page 435, note the
following requirements, which are specific to F_Port trunking for Brocade adapters:
•
The edge switch must be running in Native mode. You cannot configure trunking between the
Brocade adapters and the F_Ports of an Access Gateway module.
•
You can configure only two F_Ports in one trunk group.
See the
Brocade Adapters Administrator’s Guide
for information about configuring the
corresponding N_Port trunking on the Access Gateway and the Brocade adapter.
F_Port trunking considerations
Table 76
describes the F_Port trunking considerations.
TABLE 76
F_Port masterless considerations
Category
Description
AD
You cannot create a Trunk Area on ports with different Admin Domains. You cannot create a
Trunk Area in AD255.
Area assignment
You statically assign the area within the trunk group on the edge switch. That group is the
F_Port trunk.
The static trunk area you assign must fall within the ASIC's trunk group of the switch or
blade starting from port 0, and must be one of the port’s default areas of the trunk group.
10-bit addressing is the default mode for all dynamically created partitions in the Brocade
DCX and DCX 8510-8 platforms.
Authentication
Authentication occurs only on the F_Port trunk master port and only once per the entire
trunk. This behavior is the same as E_Port trunk master authentication. Because only one
port in the trunk does FLOGI to the switch, and authentication follows FLOGI on that port,
only that port displays the authentication details when you issue the portShow command.
NOTE: Switches in Access Gateway mode do not perform authentication.
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...