200
Fabric OS Administrator’s Guide
53-1002446-01
Firmware download on a Backbone
9
If an AP blade is present: At the point of the failover an
autoleveling
process is activated.
Autoleveling is triggered when the active CP detects a blade that contains a different version of
the firmware, regardless of which version is older. Autoleveling downloads firmware to the AP
blade, swaps partitions, reboots the blade, and copies the new firmware from the primary
partition to the secondary partition. If you have multiple AP blades, they are updated
simultaneously; however, the downloads can occur at different rates.
Autoleveling takes place in parallel with the firmware download being performed on the CPs,
but does not impact performance. Fibre Channel traffic is not disrupted during autoleveling,
but GbE traffic on AP blades may be affected.
ecp:admin>
firmwaredownload
Type of Firmware (FOS, SAS, or any application) [FOS]:
Server Name or IP Address:
10.1.2.3
User Name:
userfoo
File Name:
/home/userfoo/v7.0.0
Network Protocol (1-auto-select, 2-FTP, 3-SCP, 4-SFTP)) [1]:
Password:
<hidden>
Checking version compatibility...
Version compatibility check passed.
The following AP blades are installed in the system.
Slot Name Versions Traffic Disrupted
-----------------------------------------------------------------
4
FR4-18i v7.0.0
None
10
FR4-18i v7.0.0
None
This command will upgrade the firmware on both CPs and all AP blade(s) above.
If you want to upgrade firmware on a single CP only, please use -s option.
You may run firmwaredownloadstatus to get the status of this"
command.
This command will cause a warm/non-disruptive boot on the active CP,
but will require that existing telnet, secure telnet or SSH sessions
be restarted.
Do you want to continue [Y]:
y
The firmware is being downloaded to the Standby CP. It may take up to 10
minutes
10. Optionally, after the failover, connect to the switch, and log in again as admin. Using a separate
session to connect to the switch, enter the firmwareDownloadStatus command to monitor the
firmware download status.
sw0:FID128:admin>
firmwaredownloadstatus
[1]: Mon Mar 22 04:27:21 2010
Slot 7 (CP1, active): Firmware is being downloaded to the switch. This step
may take up to 30 minutes.
[2]: Mon Mar 22 04:34:58 2010
Slot 7 (CP1, active): Relocating an internal firmware image on the CP blade.
[3]: Mon Mar 22 04:35:29 2010
Slot 7 (CP1, active): The internal firmware image is relocated successfully.
[4]: Mon Mar 22 04:35:30 2010
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...