228
Fabric OS Administrator’s Guide
53-1002446-01
Creating a logical switch or base switch
10
NOTE
Domain ID conflicts are detected before fabric ID conflicts. If you have both a domain ID conflict and
a fabric ID conflict, only the domain ID conflict is reported.
1. Connect to the physical chassis and log in using an account with the chassis-role permission.
2. Enter the following command to create a logical switch:
lscfg --create
fabricID
[
-base
] [
-force
]
In the command syntax,
fabricID
is the fabric ID that is to be associated with the logical switch.
Specify the -base option if the logical switch is to be a base switch.
Specify the -force option to execute the command without any user prompts or confirmation.
3. Set the context to the new logical switch.
setcontext
fabricID
The
fabricID
parameter is the fabric ID of the logical switch you just created.
4. Disable the logical switch.
switchdisable
5. Configure the switch attributes, including assigning a unique domain ID.
configure
6. Enable the logical switch.
switchenable
7. Assign ports to the logical switch, as described in
“Adding and moving ports on a logical
switch”
on page 230.
Example
The following example creates a logical switch with FID 4, and then assigns domain ID 14 to it.
sw0:FID128:admin>
lscfg --create 4
About to create switch with fid=4. Please wait...
Logical Switch with FID (4) has been successfully created.
Logical Switch has been created with default configurations.
Please configure the Logical Switch with appropriate switch
and protocol settings before activating the Logical Switch.
sw0:FID128:admin>
setcontext 4
switch_4:FID4:admin>
switchdisable
switch_4:FID4:admin>
configure
Configure...
Fabric parameters (yes, y, no, n): [no]
y
Domain: (1..239) [1]
14
WWN Based persistent PID (yes, y, no, n): [no]
...
(output truncated)
WARNING: The domain ID will be changed. The port level zoning may be affected
switch_4:FID4:admin>
switchenable
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...