Fabric OS Administrator’s Guide
435
53-1002446-01
Requirements for trunk groups
22
License requirements for trunking
All types of trunking require the Trunking license. This license must be installed on each switch that
participates in trunking.
ATTENTION
After you add the Trunking license, to enable trunking functionality, you must disable and then
re-enable each port to be used in trunking, or disable and re-enable the switch.
Note the following additional license requirements:
•
For ICL trunking, each platform forming the ICL connection also requires the ICL license.
•
For F_Port trunking between a switch and a Brocade HBA, the switch connected to the HBA
also requires the Server Application Optimization (SAO) license.
See
Chapter 18, “Administering Licensing,”
for information about activating licenses.
Port groups for trunking
For trunk groups to form, several conditions must be met, one of which is that all of the ports in a
trunk group must belong to the same port group. A
port group
is a group of eight ports, based on
the user port number, such as 0–7, 8–15, 16–23, and up to the number of ports on the switch.
The maximum number of port groups is platform-specific.
Figure 69
shows the port groups for the Brocade 5100.
Ports in a port group are usually contiguous, but might not be. Refer to the hardware reference
manual for your switch for information about which ports can be used in the same port group for
trunking.
FIGURE 69
Trunk group configuration for the Brocade 5100
Requirements for trunk groups
The following requirements apply to all types of trunking:
•
The Trunking license must be installed on every switch that participates in trunking.
•
All of the ports in a trunk group must belong to the same port group.
•
All of the ports in a trunk group must be running at the same speed.
•
All of the ports in a trunk group must be configured for the same distance.
•
All of the ports in a trunk group must have the same encryption, compression, QoS, and FEC
settings.
•
Trunk groups must be between Brocade switches (or Brocade adapters, in the case of F_Port
trunking). Brocade trunking is proprietary and not supported on M-EOS or third-party switches.
•
There must be a direct connection between participating switches.
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...