Fabric OS Administrator’s Guide
77
53-1002446-01
Enabling forward error correction
4
Configuring Lossless Dynamic Load Sharing
You configure Lossless DLS switch- or chassis-wide by using the dlsSet command to specify that no
frames are dropped while rebalancing or rerouting traffic.
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the appropriate dlsSet command to enable or disable Lossless Dynamic Load Sharing.
switch:admin>
dlsset --enable -lossLess
switch:admin>
dlsset --disable -lossLess
Lossless Dynamic Load Sharing in Virtual Fabrics
Enabling Lossless Dynamic Load Sharing is optional on logical switches in Virtual Fabrics. If you
enable this feature, it must be on a per-logical switch basis and can affect other logical switches in
the fabric. XISL use must be disabled for Lossless DLS to be enabled.
How DLS affects other logical switches in the fabric
On a Brocade DCX platform, logical switch 1 consists of ports 0 through 5 in slot 1. Logical switch 2
consists of ports 6 through 10 in slot 1. The Lossless DLS feature is enabled on logical switch 1.
Because ports 0 through 10 in slot 1 belong to a logical switch where Lossless DLS is enabled, the
traffic in logical switch 2 is affected whenever traffic for logical switch 1 is rebalanced.
ATTENTION
Although Lossless DSL is enabled for a specific logical switch, you must have chassis-level
permissions to use this feature.
This effect on logical switch 2 is based on the configuration on logical switch 2:
•
If logical switch 2 has IOD enabled (iodSet only), IOD is enforced.
•
If logical switch 2 has Lossless DLS enabled, traffic is paused and resumed.
•
If logical switch 2 has no IOD (iodReset), traffic is paused and resumed.
To avoid this behavior, it is recommended to define your logical switches as follows:
•
Define logical switches that require Lossless DLS at the blade boundary.
•
Define logical switches that require Lossless DLS only using supported blades. For example, do
not use blades that support IOD, but do not support Lossless DLS.
For more information on Virtual Fabrics and chassis-level permissions, refer to
Chapter 10,
“Managing Virtual Fabrics”
.
Enabling forward error correction
Forward error correction (FEC) provides method error control during data transmission by sending
redundant data to ensure error-free transmission on a specified port or port range.
NOTE
FEC is configurable only on 16 Gbps-capable switches (Brocade 6505, 6510, and Brocade DCX
8510 Backbone family).
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...