514
Fabric OS Administrator’s Guide
53-1002446-01
Fabric configurations for interconnectivity
A
3. Physically connect the configured FC router EX_Port to the M-EOS switch, and issue the
switchShow command on the Brocade FC router.
New domains should be visible for each IFL (front domain) that connects the Fabric OS switch
to the FC router and one domain for the xlate domain.
4. Start Brocade Network Advisor and select the fabric for the M-EOS switch.
5. View the fabric topology.
New domains should be visible for each FC router connected to the M-EOS switch. Multiple
connections from the same FC router appear as only a single domain. New domains also
appear for every xlate domain that was created to import a remote device.
In Brocade Network Advisor, the M-EOS switch should appear green. Tab to Zone and verify
that the zone set configuration is correct: a blue icon beside each entry indicates that the
devices are logged in to the fabric.
6. Log in to the Fabric OS edge fabric switch and enter the nsAllShow or the nsCamShow
command.
edgeswitch:admin>
nsallshow
{
010e00 020000 03f001 04f002
4 Nx_Ports in the Fabric }
edgeswitch:admin>
nscamshow
nscam show for remote switches:
Switch entry for 1
state rev owner
known v520 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 010e00; 3;10:00:00:00:00:01:00:00;10:00:00:00:00:00:01:00;
Fabric Port Name: 20:0e:00:60:69:e2:18:b6
Permanent Port Name: 10:00:00:00:00:01:00:00
Port Index: 14
Share Area: No
Device Shared in Other AD: No
Switch entry for 3
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 03f001; 2,3;10:00:00:00:c9:44:54:04;20:00:00:00:c9:44:54:04;
FC4s: FCP
NodeSymb: [36] "Emulex LP9002 FV3.92A2 DV5-5.10A10 "
Fabric Port Name: 50:00:51:e3:70:9a:3d:e8
Permanent Port Name: 10:00:00:00:c9:44:54:04
Port Index: na
Share Area: No
Device Shared in Other AD: No
Switch entry for 4
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 04f002; 3;10:00:00:00:00:03:00:00;10:00:00:00:00:00:03:00;
Fabric Port Name: 50:06:06:91:23:45:6a:13
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...