
324
Fabric OS Administrator’s Guide
53-1002446-01
NPIV overview
15
Index Port Address Media Speed State
Proto
==============================================
0
0
010000
id
N4
Online FC F-Port
20:0c:00:05:1e:05:de:e4 0xa06601
1
1
010100
id
N4
Online FC F-Port
1 N Port + 4 NPIV public
2
2
010200
id
N4
Online FC F-Port
1 N Port + 119 NPIV public
3
3
010300
id
N4
Online FC F-Port
1 N Port + 221 NPIV public
On the Brocade DCX and DCX-4S with the FC8-64 blade, the base port is not included in the NPIV
device count. The following example shows 63 NPIV devices total.
Index Slot Port Address Media Speed State Proto
==================================================
127 12 15 a07f40 id N4 Online FC F-Port 1 N Port + 63 NPIV public
(AoQ)
Upgrade considerations
The maximum logins per switch has decreased with Fabric OS v6.4.0. When upgrading from a
release previous to Fabric OS v6.4.0 and later, the configured maximum is carried forward and may
exceed the Fabric OS v6.4.0 limit. It is recommended to reconfigure this parameter to be within the
range permitted in Fabric OS v6.4.0 and later.
Fixed addressing mode
Fixed addressing mode is the default addressing mode used in all platforms that do not have
Virtual Fabrics enabled. When Virtual Fabrics is enabled on the Brocade DCX and DCX-4S, fixed
addressing mode is used only on the default logical switch. The number of NPIV devices supported
on shared area ports (48-port blades) is reduced to 64 from 128 when Virtual Fabrics mode is
enabled.
10-bit addressing mode
The 10-bit addressing mode is the default mode for all the logical switches created in the Brocade
DCX and DCX-4S Backbones. The number of NPIV or loop devices supported on a port is 64.
Table 60
shows the number of NPIV devices supported on the Brocade DCX and DCX-4S Backbone.
TABLE 60
Number of supported NPIV devices
Platform
Virtual Fabrics
Logical switch type
NPIV support
DCX
Disabled
N/A
Yes, 127 virtual device limit.
1
DCX
Enabled
Default switch
Yes, 63 virtual device limit.
1
DCX
Enabled
Logical switch
Yes, 255 virtual device limit.
2,
3
DCX
Enabled
Base switch
No.
DCX-4S
Disabled
N/A
Yes, 255 virtual device limit.
DCX-4S
Enabled
Default switch
Yes, 255 virtual device limit.
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...