54
Fabric OS Administrator’s Guide
53-1002446-01
Equipment status
3
Equipment status
You can check the status of switch operation, High Availability features, and fabric connectivity.
Checking switch operation
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the switchShow command. This command displays a switch summary and a port
summary.
3. Check that the switch and ports are online.
4. Use the switchStatusShow command to further check the status of the switch.
Verifying High Availability features (Backbones only)
High Availability (HA) features provide maximum reliability and nondisruptive management of key
hardware and software modules.
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the chassisShow command to verify the model of the DCX and obtain a listing of all
field-replaceable units (FRUs).
3. Enter the haShow command to verify HA is enabled, the heartbeat is up, and that the HA state
is synchronized between the active and standby CP blades.
4. Enter the fanShow command to display the current status and speed of each fan in the system.
Refer to the hardware reference manual of your system to determine the appropriate values.
5. Enter the psShow command to display the current status of the switch power supplies. Refer to
the hardware reference manual of your system to determine the appropriate values.
6. Enter the slotShow -m command to display the inventory and the current status of each slot in
the system.
Example of the slot information displayed for a DCX chassis
DCX:FID128:admin>
slotshow -m
Slot Blade Type ID Model Name Status
--------------------------------------------------
1 SW BLADE 55 FC8-32 ENABLED
2 SW BLADE 51 FC8-48 ENABLED
3 SW BLADE 39 FC10-6 ENABLED
4 SW BLADE 51 FC8-48 ENABLED
5 CORE BLADE 52 CORE8 ENABLED
6 CP BLADE 50 CP8 ENABLED
7 CP BLADE 50 CP8 ENABLED
8 CORE BLADE 52 CORE8 ENABLED
9 SW BLADE 37 FC8-16 ENABLED
10 AP BLADE 43 FS8-18 ENABLED
11 SW BLADE 55 FC8-32 ENABLED
12 AP BLADE 24 FR4-18i ENABLED
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002446 01 15 December 2011 Fabric OS Administrator s Guide Supporting Fabric OS v7 0 1 ...
Page 22: ...xxii Fabric OS Administrator s Guide 53 1002446 01 ...
Page 26: ...xxvi Fabric OS Administrator s Guide 53 1002446 01 ...
Page 30: ...xxx Fabric OS Administrator s Guide 53 1002446 01 ...
Page 38: ...xl Fabric OS Administrator s Guide 53 1002446 01 ...
Page 40: ...2 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 214: ...176 Fabric OS Administrator s Guide 53 1002446 01 Management interface security 7 ...
Page 228: ...190 Fabric OS Administrator s Guide 53 1002446 01 Brocade configuration form 8 ...
Page 248: ...210 Fabric OS Administrator s Guide 53 1002446 01 Validating a firmware download 9 ...
Page 334: ...296 Fabric OS Administrator s Guide 53 1002446 01 Setting up TI over FCR sample procedure 12 ...
Page 360: ...322 Fabric OS Administrator s Guide 53 1002446 01 Encryption and compression example 14 ...
Page 404: ...366 Fabric OS Administrator s Guide 53 1002446 01 ...
Page 430: ...392 Fabric OS Administrator s Guide 53 1002446 01 Ports on Demand 18 ...
Page 502: ...464 Fabric OS Administrator s Guide 53 1002446 01 Buffer credit recovery 23 ...
Page 572: ...534 Fabric OS Administrator s Guide 53 1002446 01 Hexadecimal overview D ...
Page 584: ...546 Fabric OS Administrator s Guide 53 1002446 01 ...