31
4.6 Connecting to a Central Monitoring System
If your monitor is connected to a Central Monitoring System (CMS):
• All patient information, measurement data and settings on the monitor can be transferred to the CMS.
• All patient information,measurement data and settings can be displayed simultaneously on the monitor and
CMS.
• For some functions such as editing patient information, admitting a patient, starting/stopping NIBP meas-
urements, etc., bi-directional control can be achieved between your monitor and the CMS.
For details, refer to the CMS’s instructions for use
Chapter 5
USER SCREENS
5.1 Tailoring/Setting Your Screens
You can tailor your monitor’s screens by setting:
• Background theme and color in which each measurement’s numerics and waveform are displayed.
• Display Views
5.1.1 Changing the Display Theme
Select “Menu”
“Color Settings”.
Press “Details”, then the color setting window for each parameter will pop up.
•
Principal:
to enter into the setting form for parameter and number. 112 kinds of color for option with code
0~111, one code indicates one color.
•
Theme:
to select the monitor’s color theme, options are: Space background, Sky blue, International fashion,
and Bamboo lands in China.
•
Param BKG Color A and B:
set the background color in parameter panels. Using color A and color B as the
parameter’s background color displayed by turns. The default setting for A and B is 0. The setting range is
from 0 to 85, one number indicates one color. If the background color for the first parameter panel is color
A, then the second parameter panel will be color B, and third will be color A again, alternately displayed in
this way.
1) Quick Color Settings:
In the drop-down box “
” to select the different
theme, so as to change colors of all items in a view. Options are: Space background, Sky blue, International
fashion, and Bamboo lands in China.
5.1.2 Changing the Color of Waveforms and Parameter
1) Parameter Number Color Settings:
To set the parameter (ECG, S-T, SpO
2
, RESP, TEMP and NIBP etc.) information and the waveform color. Pro-
cedures are: Locate the cursor on the color box, rotate the Navigation Knob, and select the color.
The ECG color setting for theme, waveform and number: setting range is 0~111, the default is 16.
The S-T color setting for number: setting range is 0~111, the default is 14.
The SpO
2
color setting for theme, waveform and number: setting range is 0~111, the default is 2.
The RESP color setting for theme, waveform and number: setting range is 0~111, the default is 108.
The TEMP color setting for number: setting range is 0~111, the default is 111.
The NIBP color setting for number: setting range is 0~111, the default is 28.
The CO
2
color setting for number: setting range is 0~111, the default is 108.
The CSI color setting for number: setting range is 0~111, the default is 64.
The EMG color setting for number: setting range is 0~111, the default is 12.
The SQI color setting for number: setting range is 0~111, the default is 0.
The BS color setting for number: setting range is 0~111, the default is 91.
5.2 Display Views
A View can be configured in its Settings Window. To enter into the View Settings window for a certain view, the
procedure is: in the default screen, move the Navigation Knob on “Views” button, and select one of the view’s
label (e.g. “Big Font”), press “Settings”, then this view setting window (e.g. “Big Font View Settings” window)
pops up on the screen.
Another way to enter the View Settings window is: when the specified view is the “Current View” on screen,
Summary of Contents for 35145
Page 12: ...12 SERIE III 11 Vista anteriore Vista posteriore Lato sinistro Lato destro...
Page 13: ...13 SERIE IV 11 Vista anteriore Vista posteriore Modulo esteso Lato sinistro Lato destro...
Page 135: ...135...
Page 136: ......
Page 148: ...12 SERIES III 11 Front view Rear view Left view Right view...
Page 149: ...13 SERIES IV 11 Front view Rear view Extended Module Left view Right view...
Page 267: ...131...
Page 268: ......