• View others: if “View others” option is selected, then this monitor can view the patient information from other
bedside monitor via the central monitoring network system.
• Save Last View: Enable or disable “Save Last View” function. Select it means enable this function. If se-
lected, then the Monitor will save the last operating view as the default view when re-start the Monitor. The
factory default is “enable” this function.
Activate Views (refer to the monitor you purchased)
Description:
1) Switch views
• Select the view required to be the “Current View”, then, press “OK” button to confirm the selection.
2) Views settings
• Press “Settings” button to setup the view selected, where waveforms and parameters can be configured as
you like.
3) Activate views
• In “Views” window, pressing “Activate” button to enter the “Activate Views” window. Then, the operator can
choose the views to be activate or not, the optional views (the views can be activated) are General, Big Font,
All ECG Trace, NIBP List, OxyCRG and Short Trends. The inactivated views are display in grey.
• Only the activated views can be clockwise shifted by operating Display View Key.
Chapter 3
OPERATING INSTRUCTIONS
3.1 Installation
Devices connected to the equipment must meet the requirements of the applicable IEC standards. The
system configuration must meet the requirements of the IEC 60601-1-1 medical electrical systems stand-
ard. Any personnel who connect devices to the equipment’s signal input/output port are responsible for
providing evidence that the safety certification of the devices has been performed in accordance with IEC
60601-1-1. If you have any question, please contact the manufacturer or your local dealers.
If it is not evident from the equipment specifications whether a particular combination with other devices
is hazardous, for example, due to summation of leakage currents, please consult the manufacturers or an
expert in the field, to ensure the necessary safety of patients and all devices concerned will not be impaired
by the proposed combination.
The equipment shall be installed by personnel authorized by manufacturer.
The software copyright of the equipment is solely owned by the manufacturer. No organization or individual
shall resort to modifying, copying, or exchanging it or to any other infringement on it in any form or by any
means without due permission.
3.1.1 Unpacking and Checking
1. Open the package, take out the monitor and its accessories from the box carefully and place it in a safe,
stable and easy to watch position.
2. Open the user manual to sort the accessories according to the packing list.
• Inspect the accessories for any mechanical damages
• Check all the exposed leads and inserted accessories
• Check whether any risk or abnormity exists in the device and its accessories before using the monitor. If
any abnormity (such as broken cable or crack of the enclosure etc.) is found, do not use with the device.
Summary of Contents for 35145
Page 12: ...12 SERIE III 11 Vista anteriore Vista posteriore Lato sinistro Lato destro...
Page 13: ...13 SERIE IV 11 Vista anteriore Vista posteriore Modulo esteso Lato sinistro Lato destro...
Page 135: ...135...
Page 136: ......
Page 148: ...12 SERIES III 11 Front view Rear view Left view Right view...
Page 149: ...13 SERIES IV 11 Front view Rear view Extended Module Left view Right view...
Page 267: ...131...
Page 268: ......