Configurable Data
IP Address
- The IP address of the interface. The factory default value is 0.0.0.0
Subnet Mask
- The IP subnet mask for the interface. The factory default value is 0.0.0.0
Default Gateway
- The default gateway for the IP interface. The factory default value is
0.0.0.0
Network Configuration Protocol Current
- Choose what the switch should do following
power-up: transmit a Bootp request, transmit a DHCP request, or do nothing (none). The
factory default is None.
You cannot make this choice for both the network configuration protocol and the service
port. You will only be given the choices for Bootp or DHCP here if the service port protocol
is configured to None.
Management VLAN ID
- Specifies the management VLAN ID of the switch. It may be
configured to any value in the range of 1 - 4054. The management VLAN is used for
management of the switch. This field is configurable for administrative users and read-only
for other users.
Web Mode
- Specify whether the switch may be accessed from a Web browser. If you
choose to enable web mode you will be able to manage the switch from a Web browser.
The factory default is enabled.
Java Mode
- Enable or disable the java applet that displays a picture of the switch at the
top right of the screen. If you run the applet you will be able to click on the picture of the
switch to select configuration screens instead of using the navigation tree at the left side of
the screen. The factory default is enabled.
Web Port
- This field is used to set the HTTP Port Number. The value must be in the range
of 1 to 65535. Port 80 is the default value. The currently configured value is shown when
the web page is displayed.
Non-Configurable Data
Burned-in MAC Address
- The burned-in MAC address used for in-band connectivity if
you choose not to configure a locally administered address.
Command Buttons
Submit
- Update the switch with the values on the screen. If you want the switch to retain
the new values across a power cycle you must perform a save.
Summary of Contents for PRIMERGY BX
Page 84: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 84...
Page 94: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 94...
Page 115: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 115...
Page 174: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 174...
Page 252: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 252...
Page 284: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 284...