![Fujitsu Siemens Computers PRIMERGY BX Description Download Page 424](http://html.mh-extra.comprimergy-bx_description_2344753424.png)
System Log Management Commands Command Reference
Lan Switch and Router Blade
424
Command Mode
Privileged Exec
Display Message
Number of Traps since last reset:
The number of traps that have occurred since the last reset of
this device.
Trap Log Capacity:
The maximum number of traps that could be stored in the switch.
Log:
The sequence number of this trap.
System Up Time:
The relative time since the last reboot of the switch at which this trap occurred.
Trap:
The relevant information of this trap.
Note:
Trap log information is not retained across a switch reset.
7.7.3.1
show logging hosts
This command displays all configured logging hosts.
Syntax
show logging hosts
Default Setting
None
Command Mode
Privileged Exec
Display Message
Index (used for deleting)
IP Address
IP Address of the configured server.
Severity
The minimum severity to log to the specified address.
Port
Server Port Number.This is the port on the local host from which syslog messages are
sent.
Status
The state of logging to configured syslog hosts. If the status is disable, no logging
occurs.
7.7.4 Configuration
Commands
7.7.4.1 logging
buffered
This command enables logging to in-memory log where up to 128 logs are kept.
Summary of Contents for PRIMERGY BX
Page 84: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 84...
Page 94: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 94...
Page 115: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 115...
Page 174: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 174...
Page 252: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 252...
Page 284: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 284...