![Fujitsu Siemens Computers PRIMERGY BX Description Download Page 296](http://html.mh-extra.comprimergy-bx_description_2344753296.png)
Device Configuration Commands Command Reference
Lan Switch and Router Blade
296
The display parameters when the argument is 'all' are as follows:
Interface:
The physical slot and physical port or the logical slot and logical port.
Summary:
The summation of the statistics of all ports.
Packets Received Without Error:
The total number of packets (including broadcast
packets and multicast packets) received.
Packets Received With Error:
The number of inbound packets that contained errors
preventing them from being deliverable to a higher-layer protocol.
Broadcast Packets Received:
The total number of packets received that were directed to
the broadcast address. Note that this does not include multicast packets.
Packets Transmitted Without Error:
The total number of packets transmitted.
Transmit Packets Errors:
The number of outbound packets that could not be transmitted
because of errors.
Collisions Frames:
The best estimate of the total number of collisions on this Ethernet
segment.
This command displays detailed statistics for a specific port or for all CPU traffic based upon
the argument.
Syntax
show interface counters detailed {<slot/port> | switchport}
<slot/port> -
is the desired interface number.
switchport -
This parameter specifies whole switch or all interfaces.
Default Setting
None
Command Mode
Privileged Exec
Display Message
The display parameters when the argument is ' <slot/port>' are as follows:
Total Packets Received (Octets):
The total number of octets of data (including those in
bad packets) received on the network (excluding framing bits but including FCS octets).
This object can be used as a reasonable estimate of Ethernet utilization. If greater
precision is desired, the etherStatsPkts and etherStatsOctets objects should be sampled
before and after a common interval. The result of this equation is the value Utilization
which is the percent utilization of the Ethernet segment on a scale of 0 to 100 percent.
Packets Received 64 Octets:
The total number of packets (including bad packets)
received that were 64 octets in length (excluding framing bits but including FCS octets).
Packets Received 65-127 Octets:
The total number of packets (including bad packets)
received that were between 65 and 127 octets in length inclusive (excluding framing bits
but including FCS octets).
Summary of Contents for PRIMERGY BX
Page 84: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 84...
Page 94: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 94...
Page 115: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 115...
Page 174: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 174...
Page 252: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 252...
Page 284: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 284...