![Fujitsu Siemens Computers PRIMERGY BX Description Download Page 426](http://html.mh-extra.comprimergy-bx_description_2344753426.png)
System Log Management Commands Command Reference
Lan Switch and Router Blade
426
Syntax
logging console [<severitylevel> | <0-7>]
no logging console
[<severitylevel> | <0-7>] -
The value is specified as either an integer from 0 to 7 or
symbolically through one of the following keywords: emergency (0), alert (1), critical (2),
error (3), warning (4), notice (5), informational (6), debug (7).
no -
This command disables logging to the console.
Default Setting
None
Command Mode
Privileged Exec
7.7.4.3 logging
host
This command enables logging to a host where up to eight hosts can be configured.
Syntax
logging host <hostaddress> [ <port>] [[<severitylevel> | <0-7>]]
<hostaddress> -
IP address of the log server.
<port> -
Port number.
[<severitylevel> | <0-7>] -
The value is specified as either an integer from 0 to 7 or
symbolically through one of the following keywords: emergency (0), alert (1), critical (2),
error (3), warning (4), notice (5), informational (6), debug (7).
Default Setting
None
Command Mode
Privileged Exec
This command disables logging to hosts.
Summary of Contents for PRIMERGY BX
Page 84: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 84...
Page 94: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 94...
Page 115: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 115...
Page 174: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 174...
Page 252: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 252...
Page 284: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 284...