2.1 Function Code Tables
2-15
Chap. 2
FUNCTION C
O
DES
y codes: Link Functions
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
n
g
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
y01
RS485
Communication
1
(Station address)
1 to 255
1
-
N
Y
1
1
Y
y02
(Communications error processing)
0: Immediately trip with alarm er8
-
-
Y
Y
0
1
Y
1: Trip with alarm er8 after running for the period
specified
by
timer y03
2: Retry during the period specified by timer y03.
If
retry
fails,
trip with alarm er8. If it succeeds,
continue to run.
3:
Continue
to
run
y03
(Error processing time)
0.0 to 60.0
0.1
s
Y
Y
2.0
3
Y
y04
(Baud rate)
1: 4800 bps
-
-
Y
Y
3
1
Y
2:
9600
bps
3:
19200
bps
4:
38400
bps
y05
(Data length)
0: 8 bits
-
-
Y
Y
0
1
Y
1:
7
bits
y06
(Parity check)
0: None (Stop bit 2)
-
-
Y
Y
0
1
Y
1:
Even
parity
2:
Odd
parity
3: None (Stop bit 1)
y07
(Stop bits)
0: 2 bits
-
-
Y
Y
0
1
Y
1:
1
bit
y08
(No-response error detection time)
OFF(0): No detection
1
s
Y
Y
OFF
1
Y
1
to
60
y09
(Response latency time)
0.00 to 1.00
0.01
s
Y
Y
0.01
5
Y
y10
(Protocol selection)
0: Modbus RTU protocol
-
-
Y
Y
1
1
Y
1: SX protocol (FRENIC Loader protocol)
2:
Reserved
for
particular
manufacturers
5:
DCP3
y11
RS485
Communication
2
(Station address)
1 to 255
1
-
N
Y
1
1
Y
y12
(Communications error processing)
0: Immediately trip with alarm er8
-
-
Y
Y
0
1
Y
1: Trip with alarm er8 after running
for the period specified by timer y03
2: Retry during the period specified by timer y03.
If
retry
fails,
trip with alarm
er8
.
If it succeeds, continue to run.
3:
Continue
to
run
y13
(Error processing time)
0.0 to 60.0
0.1
s
Y
Y
2.0
3
Y
y14
(Baud rate)
1: 4800 bps
-
-
Y
Y
3
1
Y
2:
9600
bps
3:
19200
bps
4:
38400
bps
y15
(Data length)
0: 8 bits
-
-
Y
Y
0
1
Y
1:
7
bits
y16
(Parity check)
0: None (Stop bit 2)
-
-
Y
Y
0
1
Y
1:
Even
parity
2:
Odd
parity
3: None (Stop bit 1)
y17
(Stop bits)
0: 2 bits
-
-
Y
Y
0
1
Y
1:
1
bit
y18
(No-response error detection time)
OFF(0): No detection
1
s
Y
Y
OFF
1
Y
1
to
60
y19
(Response latency time)
0.00 to 1.00
0.01
s
Y
Y
0.01
5
Y
y20
(Protocol selection)
0: Modbus RTU protocol
-
-
Y
Y
0
1
Y
1: SX protocol (FRENIC Loader protocol)
2:
Reserved
for
particular
manufacturers
5:
DCP3