(Data=7
) Rising edge detector
Output
Input 1
Input 2
General-purpose timer
Rising edge detector
(Data=8
) Falling edge detector
Output
Input 1
Input 2
General-purpose timer
Falling edge detector
(Data=9
) Rising & falling edges detector
Output
Input 1
Input 2
General-purpose timer
Rising & falling edges detector
(Data=10
) Hold
Output
Input 1
Input 2
General-purpose timer
= 0
= 1
(Data=110) Increment counter
Output
Input 1
Input 2
Increment counter
Count cleared
(Data=120) Decrement counter
Output
Input 1
Input 2
Decrement counter
Count initialized
(Data=130) Timer with reset input
Output
Input 1
Input 2
ON Timer
Reset
Timer
Output
Time setting
ON
OFF
OFF
OFF ON
Input 1
Input 2
OFF
OFF
ON
OFF
ON
OFF ON
OFF
ON
OFF
ON
OFF
2-114