2-6
Code
Name
Data setting range
Incr
em
ent
Un
it
C
hang
e
w
h
en
runni
ng
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
on
wh
ich
ca
n b
e
used
E20 Signal Assignment to
Selecting function code data assigns the corresponding
(Transistor signal)
function to terminals [Y1] to [Y2], [Y3A/C] to [Y5A/C],
[Y1]
and [30A/B/C] as listed below.
-
-
N
Y
12
1
-
E21
[Y2]
Setting the value of 1000s in parentheses ( ) shown below
-
-
N
Y
78
1
-
E22
(Relay contact signal)
assigns a negative logic output to a terminal.
[Y3A/C]
-
-
N
Y
2
1
-
E23
[Y4A/C]
-
-
N
Y
12
1
-
E24
[Y5A/C]
-
-
N
Y
57
1
-
E27
[30A/B/C]
-
-
N
Y
99
1
-
0
(1000):
RUN
Inverter
running
Y
1 (1001):
FAR
Speed arrival
Y
2
(1002):
FDT
Speed
detected
Y
3
(1003):
LU
Undervoltage
detected
Y
10
(1010):
RDY
Inverter ready to run
Y
12
(1012):
SW52
-
2
MC
control
Y
25
(1025):
FAN
Cooling
fan
operation
Y
26
(1026):
TRY
Auto-resetting
Y
27
(1027):
U-DO
Universal
Do
Y
28
(1028):
OH
Overheat
early
warning
Y
30
(1030):
LIFE
Service life alarm
Y
31
(1031):
FDT2
Speed
detected
Y
35
(1035):
RUN2
Inverter output on
Y
37
(1037):
ID
Current
detected
Y
38
(1038):
ID2
Current detected 2
Y
52
(1052):
FRUN
Encoder rotating in forward direction
N
53
(1053):
RRUN
Encoder rotating in reverse direction
N
55
(1055):
AX2
Run command activated
Y
56
(1056):
THM
Motor overheat detected(PTC)
Y
57
(1057):
BRKS
Brake
control
Y
70
(1070):
DNZS
Speed
existence
N
71
(1071):
DSAG
Speed
agreement
N
72
(1072):
FAR3
Speed arrival 3
Y
73
(1073):
DACC
During
acceleration
Y
74
(1074):
DDEC
During
deceleration
Y
75
(1075):
DZR
During zero speed
N
76
(1076):
PG-ABN
PG
abnormal
N
78
(1078):
DOPEN
Door
control
Y
99
(1099):
ALM
Alarm
output
Y
101
(1101):
DECF
EN terminal detection circuit error
Y
102
(1102):
ENOFF
EN terminal OFF
Y
104
(1104):
LVD
Low voltage detected
Y
105
(1105):
EAC
Electrical angle cycle
Y
107
(1107):
DTUNE
During pole position offset tuning
N
109
(1109):
RRD
Recommended
running
direction
N
110
(1110):
ALM2
Drive continuance alarm output
Y
111
(1111):
SD
Shutdown
confirmation
Y
112
(1112):
IPL
Input power limitation
Y
114
(1114):
SW52-3
MC control(Run command activated)
Y
115
(1115):
PTD
Pole tuning done
N
116
(1116):
DSD
Detection speed direction
N
121
(1121):
TDCL
Travel direction changes lifetime early warning
Y
122
(1122):
TDCP
Travel direction changes pulse
Y
123
(1123):
SCC
Short-circuit
control
Y
124
(1124):
CEND
Deliverrance operation Calculation end
N
500
126
(1126):
PTD-Z
Pole tuning done with reference to Z-signal
N
127
(1127):
LC1
Loadcell LV1 detection
N
128
(1128):
LCF
Loadcell full load detection
N
129
(1129):
LCO
Loadcell overload detection
N
141
(1141):
CLO1
Customizable logic output signal 1
Y
142
(1142):
CLO2
Customizable logic output signal 2
Y
143
(1143):
CLO3
Customizable logic output signal 3
Y
144
(1144):
CLO4
Customizable logic output signal 4
Y
145
(1145):
CLO5
Customizable logic output signal 5
Y
146
(1146):
CLO6
Customizable logic output signal 6
Y
147
(1147):
CLO7
Customizable logic output signal 7
Y
148
(1148):
CLO8
Customizable logic output signal 8
Y
149
(1149):
CLO9
Customizable logic output signal 9
Y
150
(1150):
CLO10
Customizable logic output signal 10
Y