2.1 Function Code Tables
2-17
Chap. 2
FUNCTION C
O
DES
L codes: Lift Functions
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
n
g
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
L01 Pulse
Encoder
(Selection)
-
-
N
Y
0
1
-
A/B phase
ABS signal
0
12/15 V (Complementary / Open collector),
5 V Line driver
None
N
1
Z
N
4 Sinusoidal differential voltage (1 V p-p)
EnDat 2.1 (ECN1313 compatible)
N
5
SIN/COS (ERN1387 compatible)
N
6
BiSS-C (Sendix5873 compatible)
N
7
SSI
(ECN1313
compatible)
N
8
Hiperface
(SRS50
compatible)
N
L02
(Resolution)
360 to 60000
1
P/R
N
Y
1024
1
N
*7
L03
Magnetic Pole Position Offset
(Tuning)
-
-
N
N
0
21
N
0: Disable
Y
1: Reserved for particular manufacturers
N
3: Reserved for particular manufacturers
N
4: Enable (motor stopped)
N
5: Enable (motor rotated)
N
Note: This setting is effective if F42 = 1.
1 to 4 : It is a recommended condition that the brake is a close.
5 :
It is necessary condition that the brake is a release and without load.
L04
(Offset angle)
0.00 to 360.00 (Return value of L03)
Note: This setting is effective if F42 = 1.
0.01
deg
N
Y
0.00
5
N
L05
ACR P constant
-
-
-
Y
Y
1.5
3
N
L06
ACR I constant
-
-
-
Y
Y
0.80
5
N
L07
Auto magnetic Pole Position tuning
mode select
-
-
N
N
0
21
N
0: Disable
Y
1: Enable
N
3: Enable (with checking accuracy)
N
4: Enable (for SPM)
N
Note: This setting is effective if F42 = 1.
1 to 4 : It is a recommended condition that the brake is a close.
L09
Filter Time Constant for Reference
Speed (Final)
0.000 to 0.100
0.001
s
Y
Y
0.000
7
Y
L10
Filter Time Constant for Detected Speed
0.000 to 0.100
0.001
s
Y
Y
0.005
7
N
*7
L11
Multistep Speed Command Combination
Zero Speed
00000000
b
to 00000111
b
(0 to 7)
Note: If a binary value within the range from 00000000
b
to
00000111
b
is double-assigned, the inverter trips with alarm
Er6.
1
-
N
Y
0
1
Y
L12
Manual Speed (Middle)
1
-
N
Y
1
1
Y
L13
Maintenance Speed
1
-
N
Y
2
1
Y
L14
Creep Speed
1
-
N
Y
3
1
Y
L15
Manual Speed (Low)
1
-
N
Y
4
1
Y
L16
Low Speed
1
-
N
Y
5
1
Y
L17
Middle Speed
1
-
N
Y
6
1
Y
L18
High Speed
1
-
N
Y
7
1
Y
L19
S-curve Setting
1
0 to 50% of max. speed
1
%
Y
Y
20
1
Y
L20
2
1
%
Y
Y
20
1
Y
L21
3
1
%
Y
Y
20
1
Y
L22
4
1
%
Y
Y
20
1
Y
L23
5
1
%
Y
Y
20
1
Y
L24
6
1
%
Y
Y
20
1
Y
L25
7
1
%
Y
Y
20
1
Y
L26
8
1
%
Y
Y
20
1
Y
L27
9
1
%
Y
Y
20
1
Y
L28
10
1
%
Y
Y
20
1
Y
L29
Short Floor Operation (Holding time)
OFF(32767): Disable
0.00 to 10.00
0.01
s
N
Y
0.00
5
Y
L30
(Allowable speed)
0.00 to 6000
*1
(Equivalent with 0.00 to 200.00 Hz)
Variable
*3
N
Y
0.00
37
Y
L31
Elevator Parameter
(Speed)
1 to 4000 (Elevator speed at maximum speed of the motor)
1
mm/s
N
Y
1000
1
Y
L32
(Over speed level)
50 to 120
1
%
N
Y
120
1
N
L33
(Over speed timer)
0.000 to 0.500
0.001
s
N
Y
0.000
7
N
L34
(Moving distance
in creepless operation)
0.0 to 6553.5
0.1
mm
N
Y
0.0
3
Y
*1 The data setting range is variable. Refer to Section 2.2.
*3 The unit changes depending on the setting of C21.
*7 If the speed detection is effective, it operates.
Summary of Contents for Frenic lift
Page 1: ...LM2A series Reference Manual INR SI47 1909a E...
Page 7: ......
Page 13: ......
Page 51: ...2 38...
Page 221: ......
Page 252: ......
Page 254: ...URL http www fujielectric com...