Load cell function (LCF detection level) (L146)
Torque level set on this parameter will be understood as, torque needed to keep zero speed when car
is full.
In order to set L146 correctly, please check torque at zero speed when full load is inside car after
rollback is compensated.
Speed
(mm/s)
Run command
(FWD, REV)
ON
BRKS
L144
Mechanical brake
Opened
ON
EN1&EN2
ON
Torque
(%)
L146
LCF
ON
L147
Figure 2. Full load detection level (