2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
The function code settings for each step are as follows:
Step 1 to 14
Step No.
Block selection
Input 1
Input 2
Function 1
Function 2
Output
Note)
Step 1
U01
U02
U03
U04
U05
“SO001”
= 1 to 1999
Digital input 1
Digital input 2
Time setting
Not required
Digital output
= 2001 to 3999
Analog input 1
Analog input 2
Value 1
Value 2
Analog/digital
output
= 4001 to 6999
Analog input 1
Digital input 2
Value 1
Value 2
Analog output
Step 2
U06
U07
U08
U09
U10
“SO002”
Step 3
U11
U12
U13
U14
U15
“SO003”
Step 4
U16
U17
U18
U19
U20
“SO004”
Step 5
U21
U22
U23
U24
U25
“SO005”
Step 6
U26
U27
U28
U29
U30
“SO006”
Step 7
U31
U32
U33
U34
U35
“SO007”
Step 8
U36
U37
U38
U39
U40
“SO008”
Step 9
U41
U42
U43
U44
U45
“SO009”
Step 10
U46
U47
U48
U49
U50
“SO010”
Step 11
U51
U52
U53
U54
U55`
“SO011”
Step 12
U56
U57
U58
U59
U60
“SO012”
Step 13
U61
U62
U63
U64
U65
“SO013”
Step 14
U66
U67
U68
U69
U70
“SO014”
Output is not a function code. It indicates the output signal symbol.
Step 15 to 200
Specify a step number in U190, and set the block selection, input 1, input 2, function 1, function 2 in
U191 to U195 respectively.
Step No.
U190
Block
selection
Input 1
Input 2
Function 1
Function 2
Output
Step 15
15
U191
U192
U193
U194
U195
“SO015”
Step 16
16
“SO016”
・・・
・・・
・・・
Step 199
199
“SO199”
Step 200
200
“SO200”