2.1 Function Code Tables
2-5
Chap. 2
FUNCTION C
O
DES
E codes: Extension Terminal Functions
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
n
g
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
E01 Command
Assignment
to:
[X1]
Selecting function code data assigns the corresponding
function to terminals [X1] to [X8] as listed below.
- -
N
Y
0
1
-
E02
[X2]
Setting the value of 1000s in parentheses( ) shown below
-
-
N
Y
1
1
-
E03
[X3]
assigns a negative logic input to a terminal.
-
-
N
Y
2
1
-
E04
[X4]
-
-
N
Y
8
1
-
E05
[X5]
-
-
N
Y
60
1
-
E06
[X6]
-
-
N
Y
61
1
-
E07
[X7]
-
-
N
Y
62
1
-
E08
[X8]
-
-
N
Y
63
1
-
0
(1000):
SS1
Select multistep speed 1
Y
1 (1001):
SS2
Select multistep speed 2
Y
2
(1002):
SS4
Select multistep speed 4
Y
3
(1003):
SS8
Select multistep speed 8
Y
7
(1007):
BX
Coast-to-stop
Y
8
(1008):
RST
Reset
alarm
Y
9
(1009):
THR
Enable external alarm trip
Y
10
(1010):
JOG
Enable jogging operation
Y
24
(1024):
LE
Enable communication link
Y
25
(1025):
U-DI
Universal
DI
Y
27
(1027):
PG/Hz
Enable PG vector control
-
60
(1060):
TB1
Select torque bias 1
N
61
(1061):
TB2
Select torque bias 2
N
62
(1062):
H-TB
Hold torque bias
N
63
(1063):
BATRY
Enable battery operation
Y
64
(1064):
CRPLS
Start creepless operation
Y
65
(1065):
BRKE
Check brake control
Y
66
(1066):
DRS
Force
to
decelerate
Y
67
(1067):
UNBL
Start unbalance load compensation
N
69
:
PPT
Start magnetic pole position offset tuning
N
80
(1080):
CLC
Customizable logic cancel
Y
81
(1081):
CLTC
Customizable logic all timer clear
Y
98
:
FWD
Run
forward
Y
99
:
REV
Run
reverse
Y
100
:
NONE
No
function
assigned
Y
101
(1101):
THR2
Enable external alarm trip 2
Y
102
(1102):
RTDEC
Start reference torque decreasing
N
103
(1103):
CS-MC
Check status MC operation
Y
108
(1108):
CAN
_
LE
CAN link enable
Y
111
(1111):
BRKE1
Check brake control 1
Y
112
(1112):
BRKE2
Check brake control 2
Y
114
:
RBRK
Enable rescue operation by means of brake control
N
115
(1115):
SCCF
Short-circuit
control
feedback
Y
117
(1117):
STBY
Stand-by
mode
Y
118
:
ULSG
Unlocking safety gear operation
N
0400
Note: In the case of
THR
,
DRS
,
THR2
, data (1009), (1066), (1101) are for normal logic,
and "9", "66", "101" are for negative logic, respectively.
E10
Acceleration/Deceleration Time 3
0.00 to 99.9
Variable
s
Y
Y
1.80
12
Y
E11
Acceleration/Deceleration Time 4
Acceleration/Deceleration time is ignored at 0.00.
Variable
s
Y
Y
1.80
12
Y
E12
Acceleration/Deceleration Time 5
Variable
s
Y
Y
1.80
12
Y
E13
Acceleration/Deceleration Time 6
Variable
s
Y
Y
1.80
12
Y
E14
Acceleration/Deceleration Time 7
Variable
s
Y
Y
1.80
12
Y
E15
Acceleration/Deceleration Time 8
Variable
s
Y
Y
1.80
12
Y
E16
Acceleration/Deceleration Time 9
Variable
s
Y
Y
1.80
12
Y
E17
Acceleration/Deceleration Time 10
Variable
s
Y
Y
1.80
12
Y
E18 Run Command/
-
-
N
Y
2
1
-
Multistep
(Mode)
0:
None
Y
Speed
1:
FWD
,
REV
Y
Command Assignment to:
2:
SS1
,
SS2
,
SS4
,
SS8
Y
Agreement
3:
FWD
,
REV
,
SS1
,
SS2
,
SS4
,
SS8
Y
E19 Timer
(Time)
0.000 to 0.100
0.001
s
N
Y
0.005
7
Y