Speed
(mm/s)
Run command
(FWD, REV)
ON
BRKS
L133
Mechanical brake
Opened
ON
EN1&EN2
ON
Torque
(%)
L147
LCO
ON
Reset
ON
ON
LCO alarm
0.2 s
Figure 4. Overload detection with
LCO
alarm (L132=1)
As it can be observed, as soon as
BRKS
signal goes to ON, L144 timer starts to count. On the other
hand, as soon as mechanical brake opens torque (output current) increases but some time is needed
to stabilize torque at zero speed. When L144 timer is elapsed, because torque is over L147 level,
output function
LCO
is going to ON state. After 0.2 s, in order to make sure brake is closed before
current is removed,
LCO
alarm is issued.
L197
Warning selection switch
Set L197 bits according to Light Alarm setting.
Bit
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Warning
code
-
-
-
-
-
-
-
tCW
Warning
function
-
-
-
-
-
-
-
TDC
lifetime
early
warning
Data=0
-
-
-
-
-
-
-
Disable
Data=1
-
-
-
-
-
-
-
Enable
Default
-
-
-
-
-
-
-
0
TDC Lifetime early warning (Bit 0)
When L197 Bit 0 is set to 1 TDC ligth alarm function is enabled. Light alarm level is set by function
code L112.
For additional information please refer to TDC function (L109~L115).