L80
Brake Control (Mode)
L81
Brake Control (Operation level)
L82
Brake Control (ON delay time)
L83
Brake Control (OFF delay time)
L84
Brake Control (Brake check time)
L80 to L84 allow to perform the settings for brake control signals.
■
Brake control mode (L80)
L80 specifies the
BRKS
mode as listed below.
Data for L80
ON conditions
OFF conditions
Hold
1
- A run command is ON.
AND
- The inverter main circuit (output
gate) is kept ON during the ON
delay period specified by L82.
- After detection of the
stop speed, the OFF
delay period specified
by L83 has elapsed.
OR
- The inverter output is
shut down.
Except
conditions
given at left
2
- A run command is ON.
AND
- Output current
≥
Motor no-load
current x L81 (%).
AND
- The inverter main circuit (output
gate) is kept ON during the ON
delay period specified by L82.
■
Operation level (L81)
L81 specifies the output current that turns the
BRKS
signal ON when L80 = 2.
- Data setting range: 0 to 200 (%) (Motor no-load current reference)
■
ON delay time (L82)
L82 specifies the delay time from when the
BRKS
ON conditions are met until the
BRKS
signal is
actually turned ON.
- Data setting range: 0.00 to 10.00 (s)
■
OFF delay time (L83)
L83 specifies the delay time from when the
BRKS
OFF conditions are met until the
BRKS
signal is
actually turned OFF.
- Data setting range: 0.00 to 100.00 (s)