L09
Filter Time Constant for Reference Speed (Final)
L09 specifies the filter time constant for the reference speed (final) to be applied after the S-curve
ramp control, which reduces an impact produced at rapid acceleration/deceleration.
- Data setting range: 0.000 to 0.100 (s)
L10
Filter Time Constant for Detected Speed
L10 specifies the filter time constant for the detected speed.
- Data setting range: 0.000 to 0.100 (s)
L11 to L18
Multistep Speed Command Combination (Zero Speed to High Speed)
F01 (Speed Command)
L11 to L18 assign the combination of commands
SS1
,
SS2
and
SS4
(configured to general-purpose
input terminals) to the multistep speed commands, zero speed (C04) to high speed (C11).
- Data setting range: 00000000
b
to 00000111
b
Refer to the description of function code F01 for details.
L19 to L28
S-curve Setting 1 to 10
F01 (Speed Command)
L19 to L28 specify S-curve zones of the acceleration/deceleration to be applied when using multistep
speed commands.
The setting values are indicated in percentage to the maximum speed.
- Data setting range: 0 to 50 (%)
Refer to the description of function code F01 for details.
L29
Short Floor Operation (Holding time)
L30
Short Floor Operation (Allowable speed)
L29 and L30 specify a short floor operation that applies when a deceleration command is entered
during acceleration in a multistep speed operation in order to shorten the creep time.
The short floor operation can be also used for resetting elevators.
There are two kinds of short Floor operation (Mode1: Normal Short Floor Operation and Mode2:
Short Floor Operation with distance control). The explanation of Mode1 is described below.
Refer to the description of function code L99 for the method of changing short floor operation
and the explanation of Mode2.
■
Short floor operation holding time (L29)
L29 specifies the holding time of short floor operation. The holding time starts to count when the
speed becomes constant.
- Data setting range: OFF, 0.00 to 10.00 (s)
■
Allowable speed (L30)
L30 specifies the allowable speed, below which the short floor operation can be activated.
When the motor is running at the speed less than the one specified by L30 during acceleration in a
multistep speed operation, entering a deceleration command activates the short floor operation.
- Data setting range: 0.00 to 6000 (r/min)
Data setting range changes depending on the number of poles of motor etc. For details, refer to
section 2.2.