2.1 Function Code Tables
2-19
Chap. 2
FUNCTION C
O
DES
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
n
g
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
L90 PG Error Detection
-
-
N
Y
1
1
-
(Mode)
0: Continue to run
Y
1: Trip at alarm mode 1 with alarm ErE
N
2: Trip at alarm mode 2 with alarm ErE
N
3: Trip at alarm mode 3 with alarm ErE
N
L91
(Detection level) 0 to 50
1
%
Y
Y
10
1
N
L92
(Detection time)
0.0 to 10.0
0.1
s
Y
Y
1.0
3
N
L93
Overheat Early Warning Level
1 to 20
1
deg
Y
Y
5
1
Y
L97
Magnetic Pole Position Tuning
(Voltage)
1.00 to 50.00
0.01
%
N
Y
20.00
5
N
L98 Protecting operation selection switch
00000000
b
to 11111111
b
(0 to 255)
(In each bit, "0" for disabled, "1" for enabled.)
-
-
N
Y
01000000
(64)
1
-
Bit0: Over torque alarm (Ot)
N
Bit1: Drive continuance mode when specific alarm
Y
Bit2:
Reserved
-
Bit3:
ENOFF
signal output mode
Y
Bit4: Calculate ASR with only speed command during ULC
N
Bit5:
Reserved
-
Bit6: FAN ON/OFF control during battery operation
Y
Bit7:
Reserved
-
L99 Control
Switch
00000000
b
to 11111111
b
(0 to 255)
(In each bit, "0" for disabled, "1" for enabled.)
-
-
N
Y
00000010
(2)
1 -
Bit0: Current confirmation when starting (for synchronous motor)
N
Bit1: Rewrite magnetic pole position offset angle (tuning by
PPT
) N
Bit2: Torque bias operation with offset
N
Bit3: Select short floor operation mode
Y
Bit4: Rise direction definition for DCP
Y
Bit5: S1 bit selection for DCP
Y
Bit6:
DOPEN
function change
Y
Bit7:
Reserved
-
L101 Unlock
Safety
Gear
(Operation)
0: Normal
1: Inverse
1
-
N
Y
0
1
N
0400
L102
(Level)
10 to 200
1
%
N
Y
140
1
N
L103
(Pluse time)
0.1 to 2.0
0.1
s
N
Y
0.5
3
N
L104
(Rest time)
0,1 to 1,0
0.1
s
N
Y
0.2
3
N
L105
(Pluse)
1 to 5
1
-
N
Y
3
1
N
L106
(Speed limit)
0 to 20
1
%
N
Y
10
1
N
L108 Encoder
Rotation
(Detection
speed)
0.0 to 500.0
0.1
mm/s
N
Y
10.0
3
N
L109 Travel direction counter
*6
(Password
setting)
0000
H
to FFFF
H
0000
H
: Disable TDC function
0001
H
to FFFF
H
: Enable TDC function
-
-
N
N
0000
H
1
Y
L110
(Password unlock)
0000
H
to FFFF
H
-
-
N
N
0000
H
1
Y
L111
(Travel limit)
OFF(0.00):
Disable
0.01 to 10.00 (1.00 means 1 million times)
0.01
-
N
N
OFF
5
Y
L112
(Warning level)
OFF(0): Disable
1 to 90 (Percentage of L111)
1
%
N
N
80
1
Y
L113 (Partial number of direction
changes)
Monitor data (1.00 means 1 million times)
*Allows setting only "0.00" to reset the partial counter for
replacing.
-
-
N
N
-
5
Y
L114
(Total number of direction
changes)
Monitor data (1.00 means 1 million times)
-
-
N
N
-
5
Y
L115
(Number of counter resets)
Monitor data
-
-
N
N
-
1
Y
L117
Rescue operation by brake control
(Speed limit)
0.0 to 500.0
0.1
mm/s
N
Y
100.0
3
N
L118
(Apply time)
0.10 to 2.00
0.01
s
N
Y
0.20
5
N
L119
(Speed detection delay time)
0.00 to 3.00
0.01
s
N
Y
0.50
5
N
L120
Short circuit control
(Mode)
0: Short
circuit
always
1: Short circuit only under certain conditions
-
-
N
Y
0
1
N
L121
(Check time)
0.10 to 10.00
0.01
s
N
Y
0.30
5
N
L122
Deliverance
Operation
(Input power detection level)
1 to 200
0.01
%
N
Y
100
1
N
0500
L123
(Direction Caluculation Setup)
000b to 111b (0 to 7)
1
-
N
Y
000 (0)
1
N
Bit0:
Activation
N
Bit1: Input power level reached criteria
N
Bit2:
Directions
test
criteria
N
L124 (Direction Calculation Delay Timer)
0.00 to 1.00
1
s
N
Y
0.3
5
N
L125
UPS/batteries minimum operation level
OFF(0):
Disable
20 to 220 (200V series)
1
V
N
Y2
24
1
Y
30 to 440 (400V series)
30
*4 Reserved for particular manufacturers. Do not access this function code.
*6 These function code are excepted from normal password protection and normal data copy function. Dedicated TDC password and TDC data copy function
are available.