2-14
Code
Name
Data setting range
Incr
em
ent
Un
it
C
hang
e
w
h
en
runni
ng
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
on
wh
ich
ca
n b
e
used
U71
Customizable logic (Output selection)
Output signal 1
0:
Disable
1
-
N
Y
0
1
Y
U72
Output signal 2
1 to 200: Output of Step 1 to 200 "SO001" to "SO200"
1
-
N
Y
0
1
Y
U73
Output signal 3
1
-
N
Y
0
1
Y
U74
Output signal 4
1
-
N
Y
0
1
Y
U75
Output signal 5
1
-
N
Y
0
1
Y
U76
Output signal 6
1
-
N
Y
0
1
Y
U77
Output signal 7
1
-
N
Y
0
1
Y
U78
Output signal 8
1
-
N
Y
0
1
Y
U79
Output signal 9
1
-
N
Y
0
1
Y
U80
Output signal 10
1
-
N
Y
0
1
Y
U81
Customizable logic
(Function selection)
Output signal 1
0xxx (1xxx): Same as E01
-
-
N
Y
100
1
Y
U82
Output signal 2
8xxx: The value with 8000 added to E61
-
-
N
Y
100
1
Y
U83
Output signal 3
-
-
N
Y
100
1
Y
U84
Output signal 4
-
-
N
Y
100
1
Y
U85
Output signal 5
-
-
N
Y
100
1
Y
U86
Output signal 6
-
-
N
Y
100
1
Y
U87
Output signal 7
-
-
N
Y
100
1
Y
U88
Output signal 8
-
-
N
Y
100
1
Y
U89
Output signal 9
-
-
N
Y
100
1
Y
U90
Output signal 10
-
-
N
Y
100
1
Y
U91
Customizable logic
timer monitor
(Step selection)
0:
Disable
1
-
Y
Y
0
1
Y
1 to 200: Step 1 to 200
U100 Task process cycle setting
0: Auto select from 2, 5, 10 or 20 ms depending on
the number of steps.
2: 2 ms (Up to 10 step)
5: 5 ms (Up to 50 step)
10: 10 ms (Up to 100 step)
20: 20ms (Up to 200 step)
U121
Customizable
logic
(User parameter 1)
-9990.00 to 0.00 to 9990.00
Variable
-
Y
Y
0.00
12
Y
U122
(User parameter 2)
Variable
-
Y
Y
0.00
12
Y
U123
(User parameter 3)
Variable
-
Y
Y
0.00
12
Y
U124
(User parameter 4)
Variable
-
Y
Y
0.00
12
Y
U125
(User parameter 5)
Variable
-
Y
Y
0.00
12
Y
U126
(User parameter 6)
Variable
-
Y
Y
0.00
12
Y
U127
(User parameter 7)
Variable
-
Y
Y
0.00
12
Y
U128
(User parameter 8)
Variable
-
Y
Y
0.00
12
Y
U129
(User parameter 9)
Variable
-
Y
Y
0.00
12
Y
U130
(User parameter 10)
Variable
-
Y
Y
0.00
12
Y
U131
(User parameter 11)
Variable
-
Y
Y
0.00
12
Y
U132
(User parameter 12)
Variable
-
Y
Y
0.00
12
Y
U133
(User parameter 13)
Variable
-
Y
Y
0.00
12
Y
U134
(User parameter 14)
Variable
-
Y
Y
0.00
12
Y
U135
(User parameter 15)
Variable
-
Y
Y
0.00
12
Y
U136
(User parameter 16)
Variable
-
Y
Y
0.00
12
Y
U137
(User parameter 17)
Variable
-
Y
Y
0.00
12
Y
U138
(User parameter 18)
Variable
-
Y
Y
0.00
12
Y
U139
(User parameter 19)
Variable
-
Y
Y
0.00
12
Y
U140
(User parameter 20)
Variable
-
Y
Y
0.00
12
Y
U171 Customizable logic
(Strage area 1)
-
9990
.00 to 0.00 to 9990.00
Variable
-
Y
Y
0.00
12
Y
U172 (Strage area 2)
Variable
-
Y
Y
0.00
12
Y
U173 (Strage area 3)
Variable
-
Y
Y
0.00
12
Y
U174 (Strage area 4)
Variable
-
Y
Y
0.00
12
Y
U175 (Strage area 5)
Variable
-
Y
Y
0.00
12
Y
U190 Customizable logic setting step
Setting step
(Step number) 1 to 200
1
-
Y
Y
15
1
Y
U191
(Select block) Same as U01
-
-
N
Y
0
1
Y
U192
(Input 1) Same as U02
-
-
N
Y
100
1
Y
U193
(Input 2) Same as U03
-
-
N
Y
100
1
Y
U194
(Function 1) Same as U04
Variable
-
N
Y
0.00
12
Y
U195
(Function 2) Same as U05
Variable
-
N
Y
0.00
12
Y
U196 Customizable logic ROM version
Upper digit
(Monitor) 0 to 9999
1
-
N
N
0
1
Y
U197
(For User setting) 0 to 9999
1
-
N
Y
0
1
Y
U198 Customizable logic ROM version
Lower digit
(Monitor) 0 to 9999
1
-
N
N
0
1
Y
U199
(For User setting) 0 to 9999
1
-
N
Y
0
1
Y