2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
Torque start mode
Setting L52 data to "1" enables the torque start mode.
In this mode, the inverter increases the output voltage to generate torque along the slope specified by
the time (F24) in the rotation direction specified by a run command. When the detected speed
exceeds the starting speed (F23), the inverter starts the speed control to accelerate smoothly.
When F23 = 0.00, this mode is disabled.
In the torque start mode, a PG error may occur or the
DSAG
command on the
general-purpose output terminal may go OFF depending upon the starting speed setting.
FWD
SS1
Reference
Toruqeτ*
Starting
Speed
0
Reference
Tourqe
ON
ON
Detection Speed
Starting
Speed
0
Reference Speed
Output Gate
ON
L85 H64
F24
(%/s)
H65
100
τ
*
=
∆
∆
t
■
In case of Torque Vector control
(i) When a multistep speed command with S-curve acceleration/deceleration is enabled (F01 = 0)
If the reference speed (pre-ramp) exceeds the starting speed, the inverter activates the DC braking
operation. After the DC braking operation, the inverter activates a soft start to the starting speed.
After starting speed holding time (F24) elapses, the inverter accelerates up to the reference speed
(pre-ramp).
Speed
0
High speed
Starting
speed
FWD
SS1
SS2
SS4
ON
ON
ON
ON
High speed
E12
Acceleration/
Deceleration Time5
L19
S-curve Setting1
L24
S-curve Setting6
SW52-2
ON
Output gate
ON
L85 H64 H65 F24
DC
2-43