H76
PG Error Detection for Mode3 (Detecting level)
PG abnormal (operation choice)
PG Error Detection (Detection level)
PG Error Detection (Detection time)
H77
PG Error Detection for mode 3 (Detecting time)
Sets the detection level and time when using PG abnormal operation mode 3.- Data setting range
(H76): 0 to 50 (%)
- Data setting range (H77): 0.0 to 10.0 (s)
For details, refer to function code L90
~
L92
H80
Output Current Fluctuation Damping Gain
The inverter output current driving the motor may fluctuate due to the motor characteristics and/or
backlash in the machine. Modifying the H80 data adjusts the controls in order to suppress such
fluctuation. However, as incorrect setting of this gain may cause larger current fluctuation, do not
modify the default setting unless it is necessary.
- Data setting range (H80):0.00 to 0.40
It is a special code of the torque vector control. Refer to page 2-2 for the control mode of
the inverter.
H81
Auto Reset (Mode selection 1)
H04 Auto-reset (Times)
H05 Auto-reset (Reset interval)
H82
Auto Reset (Mode selection 2)
Certain alarm codes can be automatically reset as explained on the function codes H04 and H05 desciption.
H81 and H82 function codes defines the alarm codes which can be auto-reset.
For details, refer to function code H04 and H05.
H89
Store electronic thermal overload protection data for motor
When the electronic thermal overload protection for motor is used, thernal cumulative value of the
inverter can be reset or kept at power OFF.
Data for H89
Action
0
Clears cumulative value of thermal by inverter power OFF.
1
Retains cumulative value of thermal after inverter power OFF (factory default).
H94
Cumulative Run Time of Motor
H94 displays the cumulative run time of the motor. This feature is useful for management and
maintenance of the mechanical system. With this function code (H94), you can set the cumulative
run time of the motor to any value you choose. For example, by specifying "0", the cumulative run
time of the motor can be cleared.
- Data setting range: 0 to 65535