The block diagrams for each operation function block are given below. The setting value for
functions 1 and 2 is indicated with U04 and U05.
(2001) Adder
Output
Input 1
Input 2
+
+
U04
U05
(2002) Subtracter
Output
Input 1
Input 2
-
+
U04
U05
(2003) Multiplier
Output
Input 1
Input 2
U04
U05
×
(2004) Divider
Output
Input 1
Input 2
U04
U05
÷
(2005) Limiter
Output
Input 1
Input 2
U04
U05
(2006) Absolute value of inputs
Output
Input 1
Input 2
Absolute
value
Operation
U04
U05
(2007) Inverting adder
Output
Input 1
Input 2
+
‒
U04
-1
×
U05
+
+
(2009) Linear function
(2051) Comparator 1
Output
Input 1
Input 2
With Input 1-Input 2
≥
U04+|U05|
Output ON
With Input 1-Input 2
≤
U04-|U05|
Output OFF
(2052) Comparator 2
Output
Input 1
Input 2
With Input 1-Input 2 > U04+|U05|
Output ON
With Input 1-Input 2 < U04-|U05|
Output OFF
ON is prioritized when both conditions are satisfied.
(2053) Comparator 3
Output
Input 1
Input 2
|With Input 1-Input 2|
≥
U04+|U05|
Output ON
|With Input 1-Input 2|
≤ U
04-|U05|
Output OFF
(2054) Comparator 4
(2055) Comparator 5
Output
Input 1
Output ON when Input 1
≥ U
04
Output OFF when Input 1 < U04 – |U05|
U04
ON is prioritized when both conditions are satisfied.
Out
In
1
In
2
KA×
入力1+K
B
U04
U05
Input 1
Input 2
Output
Input 1
Input 2
Output
|With Input 1-Input 2| < U04-|U05|
Output OFF
|With Input 1-Input 2| > U04+|U05|
Output ON
2-120
Summary of Contents for Frenic lift
Page 1: ...LM2A series Reference Manual INR SI47 1909a E...
Page 7: ......
Page 13: ......
Page 51: ...2 38...
Page 221: ......
Page 252: ......
Page 254: ...URL http www fujielectric com...