2-20
Code
Name
Data setting range
Incr
em
ent
Un
it
C
hang
e
w
h
en
runni
ng
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
on
wh
ich
ca
n b
e
used
L130
Sheave diameter (Ds)
0.0 to 6553.5
0.1
mm
N
Y
0
3
Y
L131
Encoder diameter (De)
0.0 to 6553.5
0.1
mm
N
Y
0
3
Y
L132
Theta compensation band
1 to 90
1
deg
N
Y
45
1
Y
L133
Theta compensation gain lower limiter
0.0 to 1.0
0.1
-
N
Y
0.8
3
Y
L134
Backlash
(Delay Time)
0.00
to
10.00
0.01
s
N
Y
0
5
N
0500
L135
Encoder Electronic name plate
(EEPROM bank number)
0 to 255
1
-
N
Y
0
1
-
L136
(Mode) 0: Disable
1: Read
2: Write
-
-
N
Y
0
1
-
L140 Emergency sensor less for PMSM
(Current
command)
10 to 200 % (Percentage to the rated current of the motor)
1
%
N
Y
80
1
N
0600
L141
(Operation
setting) 0: Disable
1: Enable
-
-
N
N
0
1
N
L143 Load
cell
function
(Overload
mode
selection)
0: Continue
running
1: LCO
trip
- -
N
Y 0
1
N
L144
(Timer)
0.00 to 1.00
0.01
s
N
Y
0.15
5
N
L145
(LC1 detection level)
0.00 to 200.0
0.01
%
N
Y
10.00
5
N
L146
(LCF detection level)
0.00 to 200.0
0.01
%
N
Y
100.00
5
N
L147
(LCO detection level)
0.00 to 200.0
0.01
%
N
Y
110.00
5
N
L197 Warning
selection
switch
00000000
b
to 11111111
b
(0 to 255)
-
-
N
Y
00000000
(0)
1 - 0400
Bit0: TDC lifetime early warning
Y
Bit1:
Reserved
-
Bit2:
Reserved
-
Bit3:
Reserved
-
Bit4:
Reserved
-
Bit5:
Reserved
-
Bit6:
Reserved
-
Bit7:
Reserved
-
L198 Operation setting switch 1
00000000
b
to 11111111
b
(0 to 255)
-
-
N
Y
00000000
(0)
1 -
Bit0: Fixation of the carrier frequency
(1: Enable 16kHz fixed mode)
Y
Bit1: Masked parameters depending on set control mode
(1: Hidden enable (depends on F42))
Y
Bit2:
Reserved
-
Bit3:
Reserved
-
Bit4:
Reserved
-
Bit5:
Reserved
-
Bit6: Ground fail detection cancel
(1: Cancel)
Y
Bit7: Short detection cancel
(1: Cancel)
Y
L199 Operation setting switch 2
00000000
b
to 11111111
b
(0 to 255)
(In each bit, "0" for disabled, "1" for enabled.)
- -
N
Y
00000000
(0)
1 -
Bit0-Bit7: Reserved for particular manufacturer
Y
L201 Pulse output (OPC-PR/PS/PSH)
(AB pulse output rate)
1 to 10000 (1 pulse = 4 count)
-
P/R
N
Y
1024
1
Y
L202
(AB pulse output order)
0: Normal
1: Inverse
- -
N
Y 0
1
Y
L203
(Z pulse output)
0: Enable
1: Disable
- -
N
Y 1
1
Y
L204 Reserved
*4 -
-
-
N
Y
4
1
-
L205 Pulse
output
(AB pulse output hysteresis)
0: Disable
1: Enable
1 -
N
Y 1
1
Y
L207 Reserved
*4 -
-
-
N
Y
0
1
-
L208 Reserved
*4 -
-
-
N
Y
1
1
-
L209 Serial
encoder
communication
(Number of ST bits)
0 to 25
1
-
N
Y
13
1
Y
L210 Reserved
*4 -
-
-
N
Y
0
1
-
L211 Reserved
*4 -
-
-
N
Y
1
1
-
L212 Reserved
*4 -
-
-
N
Y
0
1
-
L213 Reserved
*4 -
-
-
N
Y
0
1
-
L214 Reserved
*4 -
-
-
N
Y
0
1
-
L215 Reserved
*4 -
-
-
N
Y
0
1
-
L216 Reserved
*4 -
-
-
N
Y
0
1
-
L218 Reserved
*4 -
-
-
N
Y
228
1
-
L219 Reserved
*4 -
-
-
N
Y
500
1
-
*4 Reserved for particular manufacturers. Do not access this function code.