2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
Block
selection
(U01 etc.)
Function
block
Description
Function 1
(U04 etc.)
Function 2
(U05 etc.)
6003
Temporary
change of
function
code
This function reflects the value of the specified
function code on the volatile memory (RAM)
when the input 2 becomes “0: False”. On the
other hand when the input 2 does not become
“0: False”, this function reflects the value of
input 1 instead of the function code.
The value on the volatile memory (RAM) is
cleared when the inverter is powered off, and
the value is read from the non-volatile memory
and restored when the inverter is powered on.
Set the function code group (function type
code) to the1st function code (U04, etc.).
Set the lower 2 digits of the function code No.
to the 2nd function (U05, etc.).
If the specified function code (U04, U05, etc.)
is not applicable one, this function outputs zero
value.
Because the access arbitration from some steps
at a time is not possible, only one step is
allowed to access to the same function code in
the customizable logic.
When the function code is temporarily
changed using 6003 during the customized
logic operation and if the PC loader is read or
copy to the touch panel is performed, the
temporary changed data, may be copied
instead of the non-volatile memory data.
Stop the customized logic before these
operations.
0 to 255
0 to 99
2-125