Table 3.7 Menus available in Programming mode
Main
Menu
Sub-Menu
Hierarchy
indicator
Principal Functions
0. Quick Setup: Shows only frequently used function codes.
—
—
PRG>0
1. Start-up: Sets functions for initial settings.
1 Language
PRG>1>1
Sets language to be displayed on LCD monitor.
2 Select application
PRG>1>2
Allows individual initialization of function codes that
are grouped by application.
3 Display settings
PRG>1>3
Selects content to be displayed on LCD screen.
2. Function Code: Setting screens related to function codes, such as setting/copying function code data.
1 Set data
PRG>2>1
Allows function code data to be displayed/changed.
2 Confirm data
PRG>2>2
Allows confirmation of function code settings.
3 Confirm revised data
PRG>2>3
Allows confirmation of function code changes from
factory-default settings.
4 Copy data
PRG>2>4
Reads, writes and verifies function code data between
the inverter and the keypad.
5 Initialize data
PRG>2>5
Restores function code data values to factory-default
settings.
3. INV Information: Allows monitoring of inverter operational status.
1 Operation monitor
PRG>3>1
Displays operational information.
2 I/O checking
PRG>3>2
Displays external interface information.
3 Maintenance information PRG>3>3
Displays cumulative run time and other information
used during maintenance.
4 Unit information
PRG>3>4
Allows confirmation of inverter type, serial number
and ROM version.
5 Travel direction counter
PRG>3>5
Allows confirmation and setting of travel direction
counter. This function provides the information for
replacing wire/rope.
4. Alarm Information: Displays alarm information.
1 Alarm history
PRG>4>1
Lists alarm history ( 3 previous). Also this allows
you to view the detail information on the running status at
the time when alarm occurred.
5. User Configure: Allows any settings to be made.
1 Quick setup selection
PRG>5>1
Allows function codes to be added to or deleted from
the "Quick Setup".
6. Tools: Various functions
1 Customizable logic
monitor
PRG>6>1
Previews status of each step in customizable logic.
2 Load Factor Measurement PRG>6>2
Allows measurement of the operational status of the
maximum output current and average output current.
3 Communication
Debugging
PRG>6>3
Allows monitoring and setting of function codes for
communication (S, M, W, X, Z, and etc.)
3-10