C04 to C19
Multistep Speed
F01 (Speed Command)
C04 through C19 specify zero speed to high speed for multistep speed selection. Turning
SS1
,
SS2
,
SS4
and
SS8
assigned to digital input terminals ON and OFF changes the selected speed.
- Data setting range: 0.00 to 6000 (r/min)
Data setting range changes depending on the number of poles of motor etc. For details, refer to
section 2.2.
For details, refer to function code F01.
C20
Jogging Operation Speed
H54 (Acceleration time, Jogging)
H55 (Deceleration time, Jogging)
C20 specifies the jogging operation speed.
- Data setting range: 0.00 to 6000 (r/min)
Data setting range changes depending on the number of poles of motor etc. For details, refer to
section 2.2.
■
Jogging operation
The terminal command
JOG
can be assigned to a programmable input terminal by setting "10." With
the
JOG
being ON, turning
FWD
or
REV
ON starts the jogging operation regardless of the F01
setting.
In jogging operation, the acceleration and deceleration times specified by H54 and H55 apply,
respectively.
Turning the
JOG
ON when the inverter is already in normal operation cannot switch the
inverter to jogging operation. Stop the inverter once and switch to jogging operation.
A run command (e.g.,
FWD
) and
JOG
command should be entered within 100 ms. Note
that if the input of a run command precedes that of the
JOG
command, the inverter runs in
normal operation until the input of the
JOG
command.